前往化源商城

Chemosphere 2011-01-01

Applicability of microwave-assisted extraction combined with LC-MS/MS in the evaluation of booster biocide levels in harbour sediments.

Alvaro Sánchez-Rodríguez, Zoraida Sosa-Ferrera, José Juan Santana-Rodríguez

文献索引:Chemosphere 82(1) , 96-102, (2011)

全文:HTML全文

摘要

A new sample treatment method for the determination of four common booster biocides (Diuron, TCMTB, Irgarol 1051 and Dichlofluanid) in harbour sediment samples has been developed that uses liquid chromatography-tandem mass spectrometry (LC-MS/MS) after microwave-assisted extraction, followed by clean-up and a solid phase extraction preconcentration step (MAE-SPE). The effects of different variables on MAE-SPE were studied. The recoveries obtained were greater than 75%, and the relative standard deviation was less than 7%. The detection limits ranged between 0.1 and 0.3 ng g⁻¹. The developed methodology was successfully applied to the evaluation of the presence of booster biocides in sediment samples from different harbours and marinas of Gran Canaria Island (Canary Islands, Spain).Copyright © 2010 Elsevier Ltd. All rights reserved.

相关化合物

结构式 名称/CAS号 全部文献
2-叔丁氨基-4-环丙氨基-6-甲硫基-s-三嗪 结构式 2-叔丁氨基-4-环丙氨基-6-甲硫基-s-三嗪
CAS:28159-98-0
抑菌灵 结构式 抑菌灵
CAS:1085-98-9