Analyst (Cambridge UK) 2015-06-07

Real-time monitoring of H2O2 release from single cells using nanoporous gold microelectrodes decorated with platinum nanoparticles.

Chong Xiao, Yan-Ling Liu, Jia-Quan Xu, Song-Wei Lv, Shan Guo, Wei-Hua Huang

Index: Analyst 140 , 3753-8, (2015)

Full Text: HTML

Abstract

Here, we report a self-supported nanoporous gold microelectrode decorated with well-dispersed and tiny platinum nanoparticles as an electrochemical nonenzymatic hydrogen peroxide biosensor. Nanoporous gold was fabricated by electrochemical alloying/dealloying and then small-sized platinum nanoparticles were electrodeposited uniformly on them. This novel hybrid nanostructure endows the sensor with high sensitivity and selectivity towards the reduction of hydrogen peroxide with a low detection limit of 0.3 nM. The sensor has been successfully applied for the measurement of H2O2 release from a single isolated human breast cancer cell, demonstrating its great potential for further physiological and pathological applications.

Related Compounds

Structure Name/CAS No. Articles
Sulfuric acid Structure Sulfuric acid
CAS:7664-93-9
Cysteamine Hydrochloride Structure Cysteamine Hydrochloride
CAS:156-57-0
6-benzylaminopurine Structure 6-benzylaminopurine
CAS:162714-86-5
12-O-tetradecanoylphorbol-13-acetate Structure 12-O-tetradecanoylphorbol-13-acetate
CAS:16561-29-8
Benzyl alcohol Structure Benzyl alcohol
CAS:100-51-6