Alicia A Williams, Sayo O Fakayode, Xiaodong Huang, Isiah M Warner
Index: Electrophoresis 27(21) , 4127-40, (2006)
Full Text: HTML
The optimization of separation parameters in chromatography for better separation and resolution of analytes continues to be a labor intensive procedure usually performed by a trial and error method. A multivariate analysis in the form of multilinear regression (MLR) is used to optimize separation parameters and predict the migration behavior, resolution, and resolution per unit time of achiral (4-chlorophenol, pentachlorophenol, clonazepam, and diazepam) and chiral (1,1'-binaphthyl 2,2'-dihydrogen phosphate (BNP), and 1,1'-bi-2-naphthol (BOH)) compounds in MEKC. Separations of achiral and chiral analytes were performed using an achiral (poly(sodium N-undecylenic sulfate)) molecular micelle and chiral (poly(sodium N-undecanoyl-L-leucylvalinate) or poly(sodium N-undecanoyl-L-isoleucylvalinate)) molecular micelle, respectively, at various operating temperatures, applied voltages, pH values, and molecular micelle concentrations in the BGE. The separation parameters were subsequently used as input variables for MLR models. The models were validated with independent samples. The root-mean-square percent relative error (RMS%RE) is used as a figure of merit for characterizing the performance of the migration time, resolution, and resolution per unit time models. The RMS%RE obtained for predicted migrated times, resolutions, and resolution per unit time of 4-chlorophenol, pentachlorophenol, clonazepam, diazepam, BNP, and BOH ranged between 8 and 19%. The same experimental procedure was used to optimize the separation parameters of six other chiral analytes of different compound class. The predicted migration times, resolutions, and resolution per unit time of the chiral as well as the achiral analytes compare favorably with the experimental migration times and resolutions, indicating versatility and wide applicability of the technique in MEKC.
Structure | Name/CAS No. | Molecular Formula | Articles |
---|---|---|---|
![]() |
1,1'-Binaphthyl-2,2'-diyl hydrogenphosphate
CAS:35193-63-6 |
C20H13O4P |
Multivariate approach for the enantioselective analysis in m...
2009-01-01 [J. Chromatogr. A. 1216(5) , 845-56, (2009)] |
Comparison of alkylglycoside surfactants in enantioseparatio...
1997-06-01 [Electrophoresis 18(6) , 912-918, (1997)] |
Optimization of 12 chiral analytes with 8 polymeric surfacta...
2008-10-01 [J. Chromatogr. Sci. 46(9) , 757-63, (2008)] |
Chiral selectivity of guanosine media in capillary electroph...
2011-06-01 [Electrophoresis 32(13) , 1735-41, (2011)] |
Enantioseparation using selected polysaccharides as chiral b...
1997-06-27 [J. Chromatogr. A. 773(1-2) , 331-8, (1997)] |
Home | MSDS/SDS Database Search | Journals | Product Classification | Biologically Active Compounds | Selling Leads | About Us | Disclaimer
Copyright © 2024 ChemSrc All Rights Reserved