Electroanalysis 2018-02-08

A Simple and Highly Selective Determination of Telmisartan at Sodium Dodecyl Sulfate Modified Pyrolytic Graphite Surface

Neeraj Kumar; Rajendra N. Goyal

Index: 10.1002/elan.201700764

Full Text: HTML

Abstract

A simple, facile, selective and cost effective electrochemical method is proposed for the determination of telmisartan (TMS); a drug used for hypertension. A sodium dodecyl sulfate (SDS) modified edge plane pyrolytic graphite (EPPG) is prepared by simple immersion of EPPG in SDS solution at concentration greater than critical micelle concentration (CMC). The modified sensor exhibited superior sensing properties towards the oxidation of TMS. The modified surface was characterized by using the Energy dispersive X‐ray analysis, Field Emission Scanning Electron Microscopy, Electrochemical Impedance Spectroscopy and cyclic voltammetry. The quantitative investigations of the TMS were performed by applying the square wave voltammetry. The micelles of SDS form a pseudo complex with cation radical of TMS and catalyse the oxidation. The proposed sensor shows the linear calibration plot in the concentration range of 5–100 μM with sensitivity 0.2983 μA/μM and the limit of the detection of the sensor was found to be 0.082 μM. The specificity of the developed sensor was also evaluated in the presence of commonly present interfering substances in biological samples. The amount of TMS excreted in urine of the patients undergoing treatment has also been determined. The proposed method can be effectively applied for the investigation of TMS in pharmaceutical formulations and biological samples.

Latest Articles:

Novel Green Potentiometric Method for the Determination of Lidocaine Hydrochloride and its Metabolite 2, 6‐Dimethylaniline; Application to Pharmaceutical Dosage Form and Milk

2018-03-30

[10.1002/elan.201800132]

Detection of Rocuronium in Whole Blood Using a Lipid‐Bonded Conducting Polymer and Porous Carbon Composite Electrode

2018-03-15

[10.1002/elan.201800102]

High Loading Pt Core/Carbon Shell Derived from Platinum‐Aniline Complex for Direct Methanol Fuel Cell Application

2018-03-15

[10.1002/elan.201800036]

Non‐Covalent Functionalization of Multi‐Wall Carbon Nanotubes with Polyarginine: Characterization and Analytical Applications for Uric Acid Quantification

2018-03-15

[10.1002/elan.201800034]

Voltammetric Determination of Serine using L‐cysteine Modified Platinum Electrode and Brief Exploration from the Theoretical Perspective

2018-03-15

[10.1002/elan.201700682]

More Articles...