Talanta 2011-09-30

Sensitive detection of endocrine disrupters using ionic liquid--single walled carbon nanotubes modified screen-printed based biosensors.

Ana-Maria Gurban, Lucian Rotariu, Mihaela Baibarac, Ioan Baltog, Camelia Bala

Index: Talanta 85(4) , 2007-13, (2011)

Full Text: HTML

Abstract

Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF(6)]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF(6)] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of -0.2V vs. Ag/AgCl, in linear range from 5.5 to 97.7 μM for 4-t-octylphenol and respectively, between 5.5 and 140 μM for 4-n-nonylphenol, with a response time of about 5s. The detection limit was 1.1 μM for 4-t-octylphenol, and respectively 0.4 μM for 4-n-nonylphenol (S/N=3).Copyright © 2011 Elsevier B.V. All rights reserved.


Related Compounds

  • 4-Octylphenol

Related Articles:

Liquid chromatographic-tandem mass spectrometric method for the simultaneous determination of alkylphenols polyethoxylates, alkylphenoxy carboxylates and alkylphenols in wastewater and surface-water.

2014-10-03

[J. Chromatogr. A. 1362 , 75-88, (2014)]

Determination of three alkylphenol isomers in various water samples using a new HPLC method based on a duet stationary phase.

2012-10-01

[Environ. Monit. Assess. 184(10) , 6061-70, (2012)]

Determination of alkylphenols and bisphenol A in seawater samples by dispersive liquid-liquid microextraction and liquid chromatography tandem mass spectrometry for compliance with environmental quality standards (Directive 2008/105/EC).

2012-02-03

[J. Chromatogr. A. 1223 , 1-8, (2012)]

Determination of nine environmental phenols in urine by ultra-high-performance liquid chromatography-tandem mass spectrometry.

2012-01-01

[J. Anal. Toxicol. 36(9) , 608-15, (2012)]

Analysis of endocrine disruptor compounds in marine sediments by in cell clean up-pressurized liquid extraction-liquid chromatography tandem mass spectrometry determination.

2014-12-10

[Anal. Chim. Acta 852 , 112-20, (2014)]

More Articles...