Journal of Chromatography B 2015-04-15

"Center punch" and "whole spot" bioanalysis of apixaban in human dried blood spot samples by UHPLC-MS/MS.

Naiyu Zheng, Long Yuan, Qin C Ji, Heidi Mangus, Yan Song, Charles Frost, Jianing Zeng, Anne-Françoise Aubry, Mark E Arnold

Index: J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 988 , 66-74, (2015)

Full Text: HTML

Abstract

Apixaban (Eliquis™) was developed by Bristol-Myers Squibb (BMS) and Pfizer to use as an antithrombotic/anticoagulant agent and has been recently approved for the prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation. A clinical study of apixaban, sponsored by BMS and Pfizer, included a pilot exploratory portion to evaluate the potential for future drug concentration monitoring using dried blood spot (DBS) sample collection. For DBS sample collection, a fixed blood volume was dispensed onto a DBS card by either regular volumetric pipette (venous blood collection) or capillary dispenser (finger prick blood collection). A 96-well semi-automated liquid-liquid extraction sample preparation procedure was developed to provide clean extracts for UHPLC-MS/MS quantitation. Assays using both partial-spot center punch and whole spot punch were developed and validated. The linear dynamic ranges for all the analyses were from 0.5 to 500 ng/mL. The coefficient of determination (r(2)) values was >0.9944 for all the validation runs. For the center punch approach, the intra-assay precision (%CV) was within 4.4% and inter-assay precision was within 2.6%. The assay accuracy, expressed as %Dev., was within ± 5.4% of the nominal concentrations. One accuracy and precision run was performed using the whole spot approach, the intra-assay precision (%CV) was within 7.1% and the accuracy was within ± 8.0% of the nominal concentrations. In contrast to the center punch approach, the whole spot approach eliminated the effect of hematocrit and high lipids on the analysis of apixaban in human DBS when an accurate sample blood volume was collected on DBS cards.Copyright © 2015 Elsevier B.V. All rights reserved.


Related Compounds

  • N-hexane
  • Acetonitrile
  • ethyl acetate
  • Di-n-butyl ether s...

Related Articles:

Urinary metabolic fingerprinting of mice with diet-induced metabolic derangements by parallel dual secondary column-dual detection two-dimensional comprehensive gas chromatography.

2014-09-26

[J. Chromatogr. A. 1361 , 265-76, (2014)]

The dual FAAH/MAGL inhibitor JZL195 has enhanced effects on endocannabinoid transmission and motor behavior in rats as compared to those of the MAGL inhibitor JZL184.

2014-09-01

[Pharmacol. Biochem. Behav. 124 , 153-9, (2014)]

Effect of germinated brown rice extracts on pancreatic lipase, adipogenesis and lipolysis in 3T3-L1 adipocytes.

2014-01-01

[Lipids Health Dis. 13 , 169, (2014)]

Influence of surface modification on wettability and surface energy characteristics of pharmaceutical excipient powders.

2014-11-20

[Int. J. Pharm. 475(1-2) , 351-63, (2014)]

Quantitative analysis of glycerol levels in human urine by liquid chromatography–tandem mass spectrometry

2014-04-15

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 957 , 30-5, (2014)]

More Articles...