Sensors Magazine 2011-01-01

Sensitivities of key parameters in the preparation of silver/silver chloride electrodes used in Harned cell measurements of pH.

Paul J Brewer, Daniela Stoica, Richard J C Brown

Index: Sensors (Basel.) 11(8) , 8072-84, (2011)

Full Text: HTML

Abstract

A questionnaire was completed by fourteen world leading national metrology institutes to study the influence of several variables in the preparation of Ag/AgCl electrodes on the accuracy of Harned cell measurements of pH. The performance of each institute in the last decade has been assessed based on their results in eight key comparisons, organized by the Bureau International des Poids et Measures Consultative Committee for Amount of Substance, involving the measurement of pH of phosphate, phthalate, carbonate, borate and tetroxalate buffer solutions. The performance of each laboratory has been correlated to the results of the questionnaire to determine the critical parameters in the preparation of Ag/AgCl electrodes and their sensitivities with respect to the accuracy of pH measurement. This study reveals that the parameters most closely correlated to performance in comparisons are area of electrode wire exposed to the electrolyte, diameter and porosity of the Ag sphere prior to anodisation, amount of Ag converted to AgCl during anodisation, stability times employed for electrodes to reach equilibrium in solution prior to measurement, electrode rejection criteria employed and purity of reagents.


Related Compounds

  • Silver chloride

Related Articles:

Direct conversion of silver complexes to nanoscale hexagonal columns on a copper alloy for plasmonic applications.

2013-09-21

[Phys. Chem. Chem. Phys. 15(35) , 14611-5, (2013)]

Mixed-valence metal oxide nanoparticles as electrochemical half-cells: substituting the Ag/AgCl of reference electrodes by CeO(2-x) nanoparticles.

2012-12-26

[J. Am. Chem. Soc. 134(51) , 20783-7, (2012)]

Shewanella oneidensis MR-1 chemotaxis proteins and electron-transport chain components essential for congregation near insoluble electron acceptors.

2012-12-01

[Biochem. Soc. Trans. 40(6) , 1167-77, (2012)]

Real time measurement of myocardial oxygen dynamics during cardiac ischemia-reperfusion of rats.

2012-11-21

[Analyst 137(22) , 5312-9, (2012)]

Synthesis and characterization of fumaric acid functionalized AgCl/titania nanocomposite with enhanced antibacterial activity.

2013-04-01

[J. Nanosci. Nanotechnol. 13(4) , 2826-34, (2013)]

More Articles...