Biomedical Chromatography 2003-06-01

Direct determination of estriol 3- and 16-glucuronides in pregnancy urine by column-switching liquid chromatography with electrospray tandem mass spectrometry.

Yoon Jung Yang, Jeongae Lee, Man Ho Choi, Bong Chul Chung

Index: Biomed. Chromatogr. 17(4) , 219-25, (2003)

Full Text: HTML

Abstract

Using column-switching liquid chromatography/tandem mass spectrometry (LC-MS/MS), we developed an improved analytical method of urinary estriol glucuronides. This new method is derived predominantly from maternal and fetal precursors in pregnancy. We used in the following procedure: first, we filtered urine samples with a membrane filter. Next, we directly injected the 50 microL aliquot of urine samples onto a pre-column. Then, after activating the column-switching valve, we backflushed the loaded samples onto the C(18) analytical column. Urine samples can be assayed within 20 min without any sample preparation steps. We monitored separated estriol glucuronides by negative electrospray ionization (ESI) and selected-reaction monitoring (SRM). The calibration range of estriol-3-glucuronide (E3-3G) and estriol-16-glucuronide (E3-16G) was 0.1-20 microg/mL and the linearity of the method was 0.9984 for E3-3G and 0.9987 for E3-16G. The limits of detection at a signal-to-noise (S/N) ratio of 3 were 10 ng/mL (E3-3G) and 5 ng/mL (E3-16G). The analytical recovery was over 85% and, in general, inter-day and intra-day variability for precision and accuracy were less than 10%. When applied to a pregnancy urine sample to biomedical monitoring of the function of the maternal/fetal unit, the proposed method allowed rapid and sensitive screening for the detection of E3-3G and E3-16G.Copyright 2003 John Wiley & Sons, Ltd.


Related Compounds

  • Estriol
  • Progesterone
  • Estriol 3-β-D-Glu...
  • Estriol 16α-(β-D-...
  • 2-Amino-1,3-octade...
  • Estriol 16α-(β-D-...

Related Articles:

Development of a novel magnetic molecularly imprinted polymer coating using porous zeolite imidazolate framework-8 coated magnetic iron oxide as carrier for automated solid phase microextraction of estrogens in fish and pork samples.

2014-10-01

[J. Chromatogr. A. 1365 , 35-44, (2014)]

Highly sensitive Fe₃O₄ nanobeads/graphene-based molecularly imprinted electrochemical sensor for 17β-estradiol in water.

2015-07-16

[Anal. Chim. Acta 884 , 106-13, (2015)]

Water-compatible magnetic imprinted nanoparticles served as solid-phase extraction sorbents for selective determination of trace 17beta-estradiol in environmental water samples by liquid chromatography.

2015-05-29

[J. Chromatogr. A. 1396 , 7-16, (2015)]

Cheminformatics analysis of assertions mined from literature that describe drug-induced liver injury in different species.

2010-01-01

[Chem. Res. Toxicol. 23 , 171-83, (2010)]

Calculating virtual log P in the alkane/water system (log P(N)(alk)) and its derived parameters deltalog P(N)(oct-alk) and log D(pH)(alk).

2005-05-05

[J. Med. Chem. 48 , 3269-79, (2005)]

More Articles...