Evaluation of the fit of CAD/CAM abutments.

Adam Hamilton, Roy B Judge, Joseph E Palamara, Christopher Evans

Index: Int. J. Prosthodont. 26(4) , 370-80, (2013)

Full Text: HTML

Abstract

This study aimed to compare the fit of computer-aided design/computerassisted manufacture (CAD/CAM) abutments provided by a single system with proprietary prefabricated abutments on various implant systems.Titanium CAD/CAM abutments were compared with prefabricated abutments on five different implant types. The samples were embedded in epoxy resin, sectioned longitudinally, and polished. Scanning electron microscopy was used to measure the gap between the implants and abutments at the connecting flanges and internal features. Independent t tests were used to compare data.A mean difference of 1.86 μm between the gold synOcta and CAD/CAM abutments on the Straumann Standard Plus implant was observed to be statistically significant (P = .002). Less than 0.4 μm of difference was found between the CAD/CAM and prefabricated abutments for the remaining implant types, and statistical significance was not observed. Mean differences of 34.4 μm (gold) and 44.7 μm (titanium) were observed between the CAD/ CAM and prefabricated abutments on the Straumann Standard Plus implants, which were statistically significant (P < .001). A mean difference of 15 μm was also observed between the CAD/CAM and prefabricated abutment on the NobelReplace implant, which was statistically significant (P = .026). All other groups had less that 4 μm of difference, and statistical significance was not observed.The CAD/CAM abutments appeared to have a comparable fit with prefabricated abutments for most of the systems evaluated. Design differences between the abutment connections for both Straumann implants were observed that affected the fit of internal components of the implant-abutment connections.


Related Compounds

  • Silicon dioxide
  • Nanodiamond
  • Silicon carbide

Related Articles:

Functional characterisation and permeation studies of lyophilised thiolated chitosan xerogels for buccal delivery of insulin.

2014-01-01

[Protein Pept. Lett. 21(11) , 1163-75, (2014)]

Vacuolar-ATPase isoform a2 regulates macrophages and cytokine profile necessary for normal spermatogenesis in testis.

2014-08-01

[J. Leukoc. Biol. 96(2) , 337-47, (2014)]

Hemocompatibility evaluation of small elastomeric hollow fiber membranes as vascular substitutes.

2014-10-01

[J. Biomater. Appl. 29(4) , 557-65, (2014)]

On the role of hydrophobic Si-based protective coatings in limiting mortar deterioration.

2015-11-01

[Environ. Sci. Pollut. Res. Int. 22 , 17733-43, (2015)]

Facilitated preparation of bioconjugatable zwitterionic quantum dots using dual-lipid encapsulation.

2015-01-01

[J. Colloid. Interface Sci. 437 , 140-6, (2014)]

More Articles...