Journal of UOEH 2006-06-01

Activity related to the carcinogenicity of plastic additives in the benzophenone group.

Daisuke Nakajima, Shin Asada, Shiho Kageyama, Takashi Yamamoto, Hidetoshi Kuramochi, Noriho Tanaka, Ken Takeda, Sumio Goto

Index: J. UOEH 28(2) , 143-56, (2006)

Full Text: HTML

Abstract

This study examines the activities relating to the carcinogenicity of six types of benzophenone derivatives (benzophenone, 2-hydroxy-4-octyloxybenzophenone, 2-hydroxy-4-methoxybenzophenone, 2,4-dihydroxybenzophenone, 2,2'-dihydroxy-4-methoxybenzophenone and 2,2'-dihydroxy-4,4'-dimethoxybenzophenone) currently used in plastic products as additives to serve as ultraviolet absorbing agents. The evaluation of the initiation activity used a light absorption umu-test, a luminescent umu-test and the Ames test. The promotion activity was examined by a Bhas assay, a method that uses Bhas 42 cells for the formation of transformation foci. The luminescent umu-test indicated positive initiation activity of 2-hydroxy-4-methoxybenzophenone, and pseudo-positive activity of 2,4-dihydroxybenzophenone and 2,2'-dihydroxy-4-methoxybenzophenone. In the Ames test, 2-hydroxy-4-octyloxybenzophenone showed pseudo-positive initiation activity. Conversely, 2,4-dihydroxybenzophenone indicated weak promotion activity at 10 microg/ml concentration.


Related Compounds

  • 2,4-Dihydroxybenzo...
  • DMBP

Related Articles:

Impact of induced fit on ligand binding to the androgen receptor: a multidimensional QSAR study to predict endocrine-disrupting effects of environmental chemicals.

2005-09-08

[J. Med. Chem. 48 , 5666-74, (2005)]

Metabolism of UV-filter benzophenone-3 by rat and human liver microsomes and its effect on endocrine-disrupting activity.

2015-01-15

[Toxicol. Appl. Pharmacol. 282(2) , 119-28, (2015)]

Ultra-preconcentration and determination of selected pharmaceutical and personal care products in different water matrices by solid-phase extraction combined with dispersive liquid-liquid microextraction prior to ultra high pressure liquid chromatography tandem mass spectrometry analysis.

2014-08-15

[J. Chromatogr. A. 1355 , 26-35, (2014)]

Construction of a portable sample preparation device with a magnetic poly(methacrylic acid-co-ethylene dimethacrylate) monolith as the extraction medium and its application in the enrichment of UV filters in water samples.

2014-10-01

[J. Sep. Sci. 37(19) , 2732-7, (2014)]

Rapid determination of nine parabens and seven other environmental phenols in urine samples of German children and adults.

2014-11-01

[Int. J. Hyg. Environ. Health 217(8) , 845-53, (2014)]

More Articles...