Ultrasonics 2015-12-01

Phantom evaluation of stacked-type dual-frequency 1-3 composite transducers: A feasibility study on intracavitary acoustic angiography.

Jinwook Kim, Sibo Li, Sandeep Kasoji, Paul A Dayton, Xiaoning Jiang

Index: Ultrasonics 63 , 7-15, (2015)

Full Text: HTML

Abstract

In this paper, we present phantom evaluation results of a stacked-type dual-frequency 1-3 piezoelectric composite transducer as a feasibility study for intracavitary acoustic angiography. Our previous design (6.5/30 MHz PMN-PT single crystal transducer) for intravascular contrast ultrasound imaging exhibited a contrast-to-tissue ratio (CTR) of 12 dB with a penetration depth of 2.5 mm. For improved penetration depth (>3 mm) and comparable contrast-to-tissue ratio (>12 dB), we evaluated a lower frequency 2/14 MHz PZT 1-3 composite transducer. Superharmonic imaging performance of this transducer and a detailed characterization of key parameters for acoustic angiography are presented. The 2/14 MHz arrangement demonstrated a -6 dB fractional bandwidth of 56.5% for the transmitter and 41.8% for the receiver, and produced sufficient peak-negative pressures (>1.5 MPa) at 2 MHz to induce a strong nonlinear harmonic response from microbubble contrast agents. In an in-vitro contrast ultrasound study using a tissue mimicking phantom and 200 μm cellulose microvessels, higher harmonic microbubble responses, from the 5th through the 7th harmonics, were detected with a signal-to-noise ratio of 16 dB. The microvessels were resolved in a two-dimensional image with a -6dB axial resolution of 615 μm (5.5 times the wavelength of 14 MHz waves) and a contrast-to-tissue ratio of 16 dB. This feasibility study, including detailed explanation of phantom evaluation and characterization procedures for key parameters, will be useful for the development of future dual-frequency array transducers for intracavitary acoustic angiography.Copyright © 2015 Elsevier B.V. All rights reserved.


Related Compounds

  • 1-Propanol
  • naphtho[1,2-b:5,6-...

Related Articles:

Acetonitrile adduct formation as a sensitive means for simple alcohol detection by LC-MS.

2014-11-01

[J. Am. Soc. Mass Spectrom. 25(11) , 1987-90, (2014)]

Silica-based nanofibers for electrospun ultra-thin layer chromatography.

2014-10-17

[J. Chromatogr. A. 1364 , 261-70, (2014)]

Acidogenic fermentation of Scenedesmus sp.-AMDD: Comparison of volatile fatty acids yields between mesophilic and thermophilic conditions.

2016-01-01

[Bioresour. Technol. 200 , 624-30, (2015)]

Characterization of the Intestinal Lactobacilli Community following Galactooligosaccharides and Polydextrose Supplementation in the Neonatal Piglet.

2015-01-01

[PLoS ONE 10 , e0135494, (2015)]

Organic monolith frits encased in polyether ether ketone tubing with improved durability for liquid chromatography.

2015-09-01

[J. Sep. Sci. 38 , 2938-44, (2015)]

More Articles...