Analytical Sciences 2002-06-01

Application of a pentafluorobenzyl bromide derivatization method in gas chromatography/mass spectrometry of trace levels of halogenated phenols in air, water and sediment samples.

Yoshifumi Hanada, Iwao Imaizumi, Kozo Kido, Teizi Tanizaki, Minoru Koga, Hiroaki Shiraishi, Mitsuyuki Soma

Index: Anal. Sci. 18(6) , 655-9, (2002)

Full Text: HTML

Abstract

An analytical method using pentafluorobenzyl bromide (PFBB) derivatization and gas chromatography/mass spectrometry (GC/MS) has been applied to identify and quantify chloro-, bromo- and dichlorophenols in air, water and sediment samples. Phenols in air sample were collected with a PS-2 Sep-PAK cartridge, and eluted with 2-propanol. For water and sediment samples, liquid-liquid extraction with dichloromethane was carried out, and the solvent was exchanged to 2-propanol. The phenols in the solution reacted with PFBB to form the corresponding pentafluorobenzyl esters. After extracting the derivatives into hexane, the determination was carried out by GC/MS with selected-ion monitoring. The detection limits of phenols in air, water and sediment were 0.0033 - 0.0073 microg/m3, 0.0066 - 0.0147 microg/L and 0.33 - 0.73 microg/kg, respectively. More than 90% recoveries of the halogenated phenols were obtained from real environmental samples spiked by the halogenated phenols. The three isomers of mono-chlorophenols were detected in sediment samples in the range of 5.2 - 9.2 microg/kg in wet weight basis.


Related Compounds

  • Pentafluorobenzyl...

Related Articles:

Determination of bisphenol A, triclosan and their metabolites in human urine using isotope-dilution liquid chromatography-tandem mass spectrometry.

2014-06-27

[J. Chromatogr. A. 1348 , 97-104, (2014)]

[Ureido-¹⁵N]citrulline UPLC-MS/MS nitric oxide synthase (NOS) activity assay: development, validation, and applications to assess NOS uncoupling and human platelets NOS activity.

2014-08-15

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 965 , 173-82, (2014)]

LC-MS/MS and GC-MS/MS measurement of plasma and urine di-paracetamol and 3-nitro-paracetamol: Proof-of-concept studies on a novel human model of oxidative stress based on oral paracetamol administration

2013-01-01

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 959 , 71-81, (2014)]

LC-MS/MS analysis of uncommon paracetamol metabolites derived through in vitro polymerization and nitration reactions in liquid nitrogen.

2014-09-01

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 966 , 171-8, (2014)]

GC-MS/MS and LC-MS/MS studies on unlabelled and deuterium-labelled oleic acid (C18:1) reactions with peroxynitrite (O=N-O-O⁻) in buffer and hemolysate support the pM/nM-range of nitro-oleic acids in human plasma.

2014-08-01

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 964 , 172-9, (2014)]

More Articles...