Environmental Monitoring and Assessment 2013-11-01

Dissipation and residue behavior of mepiquat on wheat and potato field application.

Fengzu Zhang, Sufang Fan, Shaowen Liu, Xuesheng Li, Canping Pan

Index: Environ. Monit. Assess. 185(11) , 9101-9, (2013)

Full Text: HTML

Abstract

A modified LC-MS method for the analysis of mepiquat residue in wheat, potato, and soil was developed and validated. A hydrophilic interaction liquid chromatographic column has been successfully used to retain and separate the mepiquat. Mepiquat residue dynamics and final residues in supervised field trials at Good Agricultural Practice (GAP) conditions in wheat, potato, and soil were studied. The limits of quantification for mepiquat in all samples were all 0.007 mg kg(-1), which were lower than their maximum residue limits. At fortification levels of 0.04, 0.2, and 2 mg kg(-1) in all samples, recoveries ranged from 77.5 to 116.4% with relative standard deviations of 0.4-7.9% (n = 5). The dissipation half-lives (T 1/2) of mepiquat in soil (wheat), wheat plants, soil (potato), and potato plants were 4.5-6.3, 3.0-5.6, 2.2-4.6, and 2.4-3.2 days, respectively. The final residues of mepiquat were below 0.153 mg kg(-1) in soil (wheat), 0.052-1.900 mg kg(-1) in wheat, below 0.072 mg kg(-1) in soil (potato), and below 1.173 mg kg(-1) in potato at harvest time. Moreover, pesticide risk assessment for all the detected residues was conducted. A maximum 0.0012% of acceptable daily intake (150 mg kg(-1)) for national estimated daily intake indicated low dietary risk of these products.


Related Compounds

  • mepiquat chloride

Related Articles:

HPLC determination of mepiquat chloride in commercial pesticide formulations.

2009-11-01

[Bull. Environ. Contam. Toxicol. 83(5) , 636-9, (2009)]

[Determination of mepiquat chloride in grape, wine and juice by liquid chromatography with electrospray tandem mass spectrometry].

2004-08-01

[Shokuhin Eiseigaku Zasshi 45(4) , 197-200, (2004)]

[Effects of mepiquat chloride on inorganic elements contents in seeds of transgenic insect-resistant cotton determined by ICP-MS].

2009-04-01

[Guang Pu Xue Yu Guang Pu Fen Xi 29(4) , 1119-22, (2009)]

Feasibility Assessment of Micro-Electrode Chip Assay as a Method of Detecting Neurotoxicity in vitro.

2011-01-01

[Front. Neuroeng. 4 , 6, (2011)]

Analysis of chlormequat and mepiquat by hydrophilic interaction chromatography coupled to tandem mass spectrometry in food samples.

2009-05-15

[J. Chromatogr. A. 1216(20) , 4402-6, (2009)]

More Articles...