Chemosphere 2016-01-01

Effectiveness of activated carbon disk for the analysis of iodine in water samples using wavelength dispersive X-ray fluorescence spectrometry.

Junseok Lee, Jinsung An, Joo-Ae Kim, Hye-On Yoon

Index: Chemosphere 142 , 72-6, (2015)

Full Text: HTML

Abstract

A novel approach using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry combined with an activated carbon (AC) disk was developed for the determination of total iodine concentrations in water samples. Dissolved iodine species (i.e., I(-) and IO3(-)) in water samples were preconcentrated on the AC disk and directly analyzed by WDXRF spectrometry. The adsorption behavior of I(-) and IO3(-) on the AC disk was assessed at varying pH levels (4, 6, and 8). The AC disks completely retained the I(-) and IO3(-) for all the pH levels tested. The calibration curve obtained from the iodine concentrations (i.e., 0, 20, 200, and 400 μg) of AC disks and the measured X-ray intensity from the WDXRF analysis showed a good linearity (R(2)=0.9960), with a relatively low limit of detection (0.575 μg). The durability of the AC disk for repeatable measurements was also assessed to validate the sustainability of the proposed method and consequently the measured X-ray intensity for the AC disks was constant until 8d of analysis time. The accuracy of the proposed AC-WDXRF method was confirmed by measuring iodine concentration spiked in drinking water using inductively coupled plasma-mass spectrometry (ICP-MS). The proposed method is simple, rapid, efficient, and environmental friendly for iodine analysis in water samples. As a precursor of disinfection by products (DBPs), it is important to determine the total iodine concentrations in raw water.Copyright © 2015 Elsevier Ltd. All rights reserved.


Related Compounds

  • Ammonium iodide
  • Potassium iodate

Related Articles:

Markers of mesterolone abuse in sulfate fraction for doping control in human urine.

2015-12-01

[J. Mass Spectrom. 50 , 1409-19, (2015)]

Metabolism of methylstenbolone studied with human liver microsomes and the uPA⁺/⁺-SCID chimeric mouse model.

2014-07-01

[Biomed. Chromatogr. 28(7) , 974-85, (2014)]

Anabolic steroids detected in bodybuilding dietary supplements - a significant risk to public health.

2015-07-01

[Drug Test. Anal. 7 , 609-18, (2015)]

Urinary cysteinyl progestogens: Occurrence and origin.

2015-08-01

[J. Steroid Biochem. Mol. Biol. 152 , 53-61, (2015)]

Improved sensitivity by use of gas chromatography-positive chemical ionization triple quadrupole mass spectrometry for the analysis of drug related substances.

2015-09-15

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 1001 , 221-40, (2015)]

More Articles...