Determination of phenoxyacid herbicides and their phenolic metabolites in surface and drinking water.
Stefano Marchese, Daniela Perret, Alessandra Gentili, Guiseppe D'Ascenzo, Angelo Faberi
Index: Rapid Commun. Mass Spectrom. 16(2) , 134-41, (2002)
Full Text: HTML
Abstract
An evaluation was made of the feasibility of using reversed-phase liquid chromatography/tandem mass spectrometry with an electrospray interface (LC/ESI-MS/MS) to measure traces of phenoxyacid herbicides and their metabolites in surface and drinking water samples. The procedure involved passing 0.5 L of river and drinking water samples through a 0.5 g graphitized carbon black (GCB) extraction cartridge. Recovery was higher than 85% irrespective of the aqueous matrix in which the analytes were dissolved. A conventional 4.6-mm i.d. reversed-phase LC C-18 column operating with a mobile phase flow rate of 1 mL/min was used to chromatograph the analytes. A flow of 200 microL/min of the column effluent was diverted to the ESI source. The limits of detection (signal-to-noise ratio = 3) of the method for the pesticides considered in drinking and surface water samples are less than 0.1 ng/L for phenoxyacid herbicides, and about 5-10 ng/L for their metabolites (2,4-dichlorophenol and 4-chloro-2-methylphenol).Copyright 2001 John Wiley & Sons, Ltd.
Related Compounds
Related Articles:
2008-03-01
[J. Sep. Sci. 31(4) , 746-52, (2008)]
2008-09-01
[J. Sep. Sci. 31(16-17) , 3021-9, (2008)]
1987-02-01
[Scand. J. Work. Environ. Health 13(1) , 9-17, (1987)]
1984-01-01
[Sud. Med. Ekspert. 27(3) , 47-9, (1984)]
1991-01-01
[Arch. Toxicol. Suppl. 14 , 174-8, (1991)]