Journal of chromatography. A 2013-04-12

Characterization of functionalized polyolefins by high-temperature two-dimensional liquid chromatography.

Anton Ginzburg, Tibor Macko, Frank Malz, Michael Schroers, Irene Troetsch-Schaller, Jan Strittmatter, Robert Brüll

Index: J. Chromatogr. A. 1285 , 40-7, (2013)

Full Text: HTML

Abstract

High-temperature two-dimensional liquid chromatography (HT 2D-LC) was developed for the separation and characterization of functional polyolefins. Therefore, the key experimental parameters, namely the injection volume, the mobile phase composition, the flow rate in SEC and the time and phase of sampling into the second dimension, were systematically varied and their influence on the resolution of separation were studied. The HPLC separation of ethylene-vinylacetate waxes was realized using silica gel as stationary phase and a solvent gradient decalin→cyclohexanone, while SEC separations were realized in the chromatographic system polystyrene divinyl benzene column/1,2,4-trichlorobenzene. By choosing suitable experimental parameters, the run time needed for one complete 2D-LC analysis of a polymer sample was shortened from about 200 min to 100 min. However, the developed method failed to adsorb polypropylene and ethylene/1-butene copolymers grafted with 13 or 3 mol.% of methyl methacrylate respectively. Using porous graphite as a stationary phase and a solvent gradient 1-decanol→1,2,4-trichlorobenzene as mobile phase 2D-LC separations of both grafted polyolefins were realized.Copyright © 2013 Elsevier B.V. All rights reserved.


Related Compounds

  • poly(methyl methac...
  • poly(methyl methac...
  • Ethylene-vinyl ace...

Related Articles:

Computed gray levels in multislice and cone-beam computed tomography.

2013-07-01

[Am. J. Orthod. Dentofacial Orthop. 144(1) , 147-55, (2013)]

Hetero diels-alder chemistry for the functionalization of single-walled carbon nanotubes with cyclopentadienyl end-capped polymer strands.

2013-04-25

[Macromol. Rapid Commun. 34(8) , 672-80, (2013)]

Non-topography-guided photorefractive keratectomy for the correction of residual mild refractive errors after ICRS implantation and CXL in keratoconus.

2014-04-01

[J. Refract. Surg. 30(4) , 266-71, (2014)]

Fabrication of ordered poly(methyl methacrylate) nanobowl arrays using SiO2 colloidal crystal templates.

2014-06-01

[J. Nanosci. Nanotechnol. 14(6) , 4622-5, (2014)]

Modification of Pd-Fe nanoparticles for catalytic dechlorination of 2,4-dichlorophenol.

2013-04-01

[Sci. Total Environ. 449 , 157-67, (2013)]

More Articles...