Acoustically enhanced multicomponent NAPL ganglia dissolution in water saturated packed columns.

Constantinos V Chrysikopoulos, Eric T Vogler

Index: Environ. Sci. Technol. 38(10) , 2940-5, (2004)

Full Text: HTML

Abstract

The impact of acoustic pressure waves on multicomponent nonaqueous phase liquid (NAPL) ganglia dissolution in water saturated columns packed with glass beads was investigated. Laboratory data from dissolution experiments with two and three component NAPL mixtures suggested that acoustic waves significantly enhance ganglia dissolution due to the imposed oscillatory interstitial water velocity. The dissolution enhancement was shown to be directly proportional to the acoustic wave frequency. Furthermore, it was demonstrated that the greatest dissolution enhancement in the presence of acoustic waves is associated with the component of the NAPL mixture having the smallest equilibrium aqueous solubility. Finally, square shaped acoustic waves were shown to lead to greater NAPL dissolution enhancement compared to sinusoidal and triangular acoustic waves. The results of this study suggested that aquifer remediation using acoustic waves is a promising method particularly for aquifers contaminated with NAPLs containing components with very low equilibrium aqueous solubilities.


Related Compounds

  • 1,1,2-Trichloroeth...

Related Articles:

Development of QSAR models for predicting hepatocarcinogenic toxicity of chemicals.

2009-09-01

[Eur. J. Med. Chem. 44 , 3658-64, (2009)]

Development of a new extraction method based on counter current salting-out homogenous liquid-liquid extraction followed by dispersive liquid-liquid microextraction: Application for the extraction and preconcentration of widely used pesticides from fruit juices.

2016-01-01

[Talanta 146 , 772-9, (2015)]

Development of counter current salting-out homogenous liquid-liquid extraction for isolation and preconcentration of some pesticides from aqueous samples.

2015-07-23

[Anal. Chim. Acta 885 , 122-31, (2015)]

A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

2015-12-01

[Biomed. Chromatogr. 29 , 1921-31, (2015)]

Photovoltaic effect in individual asymmetrically contacted lead sulfide nanosheets.

2015-03-21

[Nanoscale 7(11) , 4875-83, (2015)]

More Articles...