Inhalation Toxicology 2006-07-01

Chlorosilane acute inhalation toxicity and development of an LC50 prediction model.

Paul A Jean, Robert H Gallavan, Gary B Kolesar, Waheed H Siddiqui, Jon A Oxley, Robert G Meeks

Index: Inhal. Toxicol. 18(8) , 515-22, (2006)

Full Text: HTML

Abstract

The acute inhalation toxicity of 10 chlorosilanes was investigated in Fischer 344 rats using a 1-h whole-body vapor inhalation exposure and a 14-day recovery period. The median lethal concentration (LC50(1)) for each material was calculated from the nominal exposure concentrations and mortality. Experimentally derived LC50(1) values for monochlorosilanes (4257-4478 ppm) were greater than those for dichlorosilanes (1785-2092 ppm), which were greater than those for trichlorosilanes (1257-1611 ppm). Apparent was a strong structure-activity relationship (r2 = .97) between chlorine content and LC50(1) value. Estimated LC50(1) values for mono-, di-, and trichlorosilanes were determined to be 3262, 1639, and 1066 ppm, respectively, utilizing this relationship and the lower limit of the 95% prediction interval. The LC50(1) values determined in this series of studies were greater than that reported for hydrogen chloride (3124 ppm), when expressed on a chlorine equivalence basis (3570-5248 ppm), demonstrating that the acute toxicity of these chlorosilanes is similar to or less than that for hydrogen chloride. The good correlation between chlorine content and LC50(1) provides a sound basis for estimation of LC50(1) for chlorosilanes not already evaluated. The use of structure-activity relationships is consistent with the chemical industry and federal agency initiatives to reduce, refine, and/or replace the use of animals in testing without compromising the quality of health and safety assessments.


Related Compounds

  • Dichlorosilane

Related Articles:

Microfabrication, separations, and detection by mass spectrometry on ultrathin-layer chromatography plates prepared via the low-pressure chemical vapor deposition of silicon nitride onto carbon nanotube templates.

2015-07-24

[J. Chromatogr. A. 1404 , 115-23, (2015)]

Plasma-enhanced modification of xanthan gum and its effect on rheological properties.

2005-05-04

[J. Agric. Food Chem. 53(9) , 3618-25, (2005)]

Evaluation of polymers based on a silicone backbone as pseudostationary phases for electrokinetic chromatography.

1999-09-01

[Electrophoresis 20(12) , 2412-9, (1999)]

Acute and subacute inhalation toxicity of dichlorosilane in male ICR mice.

1996-01-01

[Arch. Toxicol. 70(3-4) , 218-23, (1996)]

Ice-water interface migration by temperature controlling for stretching of DNA molecules.

2004-12-01

[J. Biomol. Struct. Dyn. 22(3) , 331-7, (2004)]

More Articles...