Journal of Fluorescence 2011-07-01

An enhancement of europium-/gadolinium- diphacinone -DL-histidine- cetylpyridine bromide system for the determination of diphacinone in serum.

Meiqiang Cai, Xiaohong Chen, Micong Jin

Index: J. Fluoresc. 21(4) , 1349-56, (2011)

Full Text: HTML

Abstract

As one of the first generation anticoagulant rodenticide, diphacinone (DPN) was extensively used in China, and often occurred accidental and intentional intoxications. To meet the needs of clinical emergency rescue, a simple, rapid and sensitive method was necessary for the determination of DPN in serum. In this paper, a fluorimetric method using a ternary europium-gadolinium-DPN-DL-histidine-cetylpyridine bromide system was developed. The fluorescence intensity was measured with a 1 cm quartz cell at 335 nm excitation wavelength and 612 nm emission wavelength. The fluorescence intensity of the europium-DPN- DL- histidine complex system was further enhanced by using gadolinium ion (Gd(3+)) in a cetylpyridine bromide (CPB) colloid-type suspension. By adding Gd(3+) at pH 8.5 to 9.5 in the presence of an ammonia-ammonium chloride buffer solution, about a 100-fold enhancement of the fluorescence intensity was achieved. The enhanced fluorescence intensity showed a good linear relationship with the DPN concentration from 0.01 mg/L to 5.0 mg/L. The limit of detection was 0.001 mg/L in serum. The established method was used to determine DPN in real human serum in clinical specimens. The luminescence mechanism was discussed in detail. In the fluorescence system of the europium-gadolinium-DPN-DL-histidine-CPB, the CPB not only acted as the surfactant but also acted as the energy donor.© Springer Science+Business Media, LLC 2011


Related Compounds

  • diphacinone
  • Phenindione

Related Articles:

Acute toxicity of diphacinone in Northern bobwhite: effects on survival and blood clotting.

2010-09-01

[Ecotoxicol. Environ. Saf. 73(6) , 1159-64, (2010)]

Diagnostic importance of vitamin K1 and its epoxide measured in serum of dogs exposed to an anticoagulant rodenticide.

1989-10-01

[Am. J. Vet. Res. 50(10) , 1704-9, (1989)]

What is your diagnosis? Rodenticide poisoning in a dog.

1999-04-15

[J. Am. Vet. Med. Assoc. 214(8) , 1157-8, (1999)]

Reversed-phase ion-pair liquid chromatographic determination of chlorophacinone and diphacinone in steam-rolled oat baits and steam-rolled oat/wax baits.

2013-12-01

[J. AOAC Int. 81(2) , 349-57, (1998)]

Effect of diphacinone on blood coagulation in Spermophilus beecheyi as a basis for determining optimal timing of field bait applications.

2002-07-01

[Pest Manag. Sci. 58(7) , 736-8, (2002)]

More Articles...