Journal of Computer Assisted Tomography 2013-01-01

Comparison of multidetector computed tomography angiography and cholangiography performed at 80 and 120 kVp in live liver donors.

Steffen Huber, Daniel Cornfeld, Sukru H Emre, Gary M Israel

Index: J. Comput. Assist. Tomogr. 37(3) , 443-9, (2013)

Full Text: HTML

Abstract

The objective of this study was to compare the radiation exposure and image quality of contrast-enhanced multidetector computed tomography angiography (CTA) and computed tomography cholangiography (CTC) performed for living liver donor evaluation using 80 and 120 kVp.Ninety-three potential liver donors who underwent preoperative contrast-enhanced 64 multidetector CTA and CTC were retrospectively divided into 2 groups: at 80 and at 120 kVp. An institutional review board waiver was obtained. Signal-to-noise ratio and contrast-to-noise ratio of the hepatic artery and common bile duct were obtained. The dose-length product was recorded. Image quality and visibility of hepatic artery and biliary tract anatomy were evaluated. Mann-Whitney U test was used for statistical evaluation.Mean hepatic artery/common bile duct signal-to-noise ratio was 28.9/28.6 (SD, 14.2/10.0) at 80 kVp and 27.6/25.8 (SD, 8.0/6.2) at 120 kVp (P = 0.61/0.099). Mean hepatic artery/common bile duct contrast-to-noise ratio was 24.8/23.3 (SD, 12.9/8.6) at 80 kVp and 22.2/19.3 (SD, 7.7/5.0) at 120 kVp (P = 0.76/0.005). Mean CTA/CTC dose-length product was 279/281 (SD, 42/52) mGy-cm at 80 kVp and 407/451 (SD, 208/243) mGy-cm at 120 kVp (P = 0.026/0.002). Computed tomography cholangiography image quality and visibility of biliary tract anatomy were not significantly different at 80 versus 120 kVp (all P > 0.13). Computed tomography angiography image quality was significantly lower (P < 0.01), and the noise scores significantly higher (P < 0.01) at 80 versus 120 kVp, but diagnostic.Contrast-enhanced CTA and CTC performed at 80 kVp result in comparable image quality and anatomical evaluation with reduced radiation exposure when compared with 120 kVp.


Related Compounds

  • iodipamide
  • Iohexol

Related Articles:

Radiographic features of potential donor livers that precluded donation.

2014-04-01

[AJR Am. J. Roentgenol. 202(4) , W343-8, (2014)]

Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: A comparative analysis of image quality and radiation exposure

2012-07-01

[Eur. J. Radiol. 81(7) , 1405-12, (2012)]

Intravenous 64-multi-detector row CT-cholangiography of porcine livers: a feasibility study with definition of the temporal window for optimal bile duct delineation.

2010-09-01

[J. Hepatobiliary. Pancreat. Sci. 17(5) , 666-72, (2010)]

Distributing pattern of the bile duct of the caudate lobe on computed tomography with drip infusion cholangiography and its surgical significance.

2004-01-01

[Hepatogastroenterology. 51(55) , 29-32, (2004)]

MR and CT cholangiography in evaluation of the biliary tract.

1998-10-01

[Acta radiol. 39(5) , 557-63, (1998)]

More Articles...