American Industrial Hygiene Association Journal 1994-04-01

Generation of hexahydrophthalic anhydride atmospheres in a controlled human-use test chamber.

B A Jönsson, H Welinder, G Skarping

Index: Am. Ind. Hyg. Assoc. J. 55(4) , 330-8, (1994)

Full Text: HTML

Abstract

A method for generating controlled atmospheres of hexahydrophthalic anhydride (HHPA) in an 8 m3 exposure chamber was developed. The permeation principle was used for gaseous HHPA generation. HHPA concentration was monitored by sampling on XAD-2 tubes and by a Fourier-transform infrared (FTIR) spectrometer using the partial least-square quantitative method. The repeatability of the FTIR was 5%, the reproducibility 12%, and the limit of detection 10 micrograms/m3. A bubbler method determined the sum of HHPA and HHP acid by using gas chromatography/mass spectrometry detection after derivatization with methanol/boron trifluoride. The precision of the work-up procedure was 3% and the recovery was 94% at 300 ng sampled amount of HHPA. The limit of detection was 10 ng HHPA. The variation in the permeation rate was 3% over 3 days. Different concentrations in the exposure chamber were generated by changing the temperature of the permeation tubes. The generated HHPA concentration range, at human exposure, was 3-90 micrograms/m3. The concentration at one temperature was reproducible even after major changes in the temperature. The coefficient of variation (CV) of six samples from different places in the breathing zone was 3%. The variation in the concentration, during an 8-hour human exposure at 10 micrograms/m3, was 3%. Time-weighted averages (8 hour) for human exposures of 10 micrograms/m3 (CV = 15%; n = 6); 37 micrograms/m3 (CV = 5%; n = 5); and 81 micrograms/m3 (CV = 6%; n = 9) were obtained at intended concentrations of 10 micrograms/m3, 40 micrograms/m3, and 80 micrograms/m3. The loss of HHPA in the exposure chamber was 54% (CV = 17%).(ABSTRACT TRUNCATED AT 250 WORDS)


Related Compounds

  • Lura

Related Articles:

Determination of hexahydrophthalic acid and methylhexahydrophthalic acid in plasma after derivatisation with pentafluorobenzyl bromide using gas chromatography and mass spectrometric detection.

1997-04-11

[J. Chromatogr. B. Biomed. Sci. Appl. 691(2) , 331-9, (1997)]

Toxicokinetics and biological monitoring in experimental exposure of humans to gaseous hexahydrophthalic anhydride.

1993-06-01

[Scand. J. Work. Environ. Health 19(3) , 183-90, (1993)]

Method for the biological monitoring of hexahydrophthalic anhydride by the determination of hexahydrophthalic acid in urine using gas chromatography and selected-ion monitoring.

[J. Chromatogr. A. 572(1-2) , 117-31, (1991)]

Occupational exposure to hexahydrophthalic anhydride: air analysis, percutaneous absorption, and biological monitoring.

1993-01-01

[Int. Arch. Occup. Environ. Health 65(1) , 43-7, (1993)]

Methods for the identification of chemical respiratory allergens in rodents: comparisons of cytokine profiling with induced changes in serum IgE.

2003-01-01

[J. Appl. Toxicol. 23(4) , 199-207, (2003)]

More Articles...