Nuclear Medicine Communications 2011-10-01

Renogram comparison of p-[(18)F]fluorohippurate with o-[(125)I]iodohippurate and [(99m)Tc]MAG3 in normal rats.

Gopal Pathuri, Kaustuv Sahoo, Vibhudutta Awasthi, Hariprasad Gali

Index: Nucl. Med. Commun. 32(10) , 908-12, (2011)

Full Text: HTML

Abstract

We recently identified p-[(18)F]fluorohippurate ([(18)F]PFH) as a potential positron emission tomography (PET) renal agent. The objective of this study was to compare renogram parameters of [(18)F]PFH with o-[(125)I]iodohippurate ([(125)I]OIH) as a surrogate for the renal imaging gold standard (131)I-OIH and with a clinically used agent [(99m)Tc]MAG3.Normal Sprague-Dawley rats (n=4) were sequentially imaged on days 1, 2, and 3 using [(99m)Tc]MAG3 (18.1-19.1 MBq, dynamic planar), [(18)F]PFH (2.6-4.1 MBq, dynamic PET), and [(125)I]OIH (7.7-13.5 MBq, dynamic planar), respectively. The PET data were binned into frames of 30 s each, whereas the planar images were acquired as 30 s per frame. Regions of interest were drawn on both kidneys, and decay-corrected renograms were generated for each imaging modality.The PET-derived [(18)F]PFH renograms revealed an average time-to-peak (T(max)) of 4.8±2.4 min, which was comparable to the T(max) of 3.6±1.7 min and 4.3±1.7 min for [(125)I]OIH and [(99m)Tc]MAG3 renograms, respectively. The average time-to-half-maximal activity was found to be 16.6±6.6 min, 8.3±2.4 min, and more than 20 min with [(18)F]PFH, [(125)I]OIH, and [(99m)Tc]MAG3, respectively.Compared with [(99m)Tc]MAG3, the renogram parameters of [(18)F]PFH seem to be closer to those obtained from [(125)I]OIH. The quality of the renogram and the images obtained with the dynamic [(18)F]PFH PET study were remarkably better than those obtained with the [(99m)Tc]MAG3 dynamic planar imaging study.


Related Compounds

  • 2'-iodohippuric ac...

Related Articles:

Renal brush border enzyme-cleavable linkages for low renal radioactivity levels of radiolabeled antibody fragments.

2013-02-20

[Bioconjug. Chem. 24(2) , 291-9, (2013)]

Renal function and cardiopulmonary bypass in pediatric cardiac surgical patients.

2006-10-01

[Pediatr. Nephrol. 21(10) , 1446-51, (2006)]

123I-hippuran renal scintigraphy with evaluation of single-kidney clearance for predicting renal scarring after acute urinary tract infection: comparison with (99m)Tc-DMSA scanning.

2003-11-01

[J. Nucl. Med. 44(11) , 1755-60, (2003)]

Preclinical evaluation of 99mTc(CO)3-aspartic-N-monoacetic acid, a renal radiotracer with pharmacokinetic properties comparable to 131I-o-iodohippurate.

2012-08-01

[J. Nucl. Med. 53(8) , 1277-83, (2012)]

Evaluation of (123)I-orthoiodohippurate single kidney clearance rate by renal sequential scintigraphy in a large cohort of likely normal subjects aged between 0 and 18 years.

2006-12-01

[Eur. J. Nucl. Med. Mol. Imaging 33(12) , 1483-90, (2006)]

More Articles...