Analytical and Bioanalytical Chemistry 2003-04-01

On-line ion-exchange preconcentration and determination of traces of platinum by electrothermal atomic absorption spectrometry.

M M González García, F Sánchez Rojas, C Bosch Ojeda, A García de Torres, J M Cano Pavón

Index: Anal. Bioanal. Chem 375 , 1229-1233, (2003)

Full Text: HTML

Abstract

A method to determine trace amounts of platinum in different samples based on electrothermal atomic absorption spectrometry is described. The preconcentration step is performed on a chelating resin microcolumn [1,5-bis(2-pyridyl)-3-sulfophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)] placed in the autosampler arm. The combination of a peristaltic pump for sample loading and the atomic absorption spectrometer pumps for elution through a selection valve simplifies the hardware. The peristaltic pump and the selection valve are easily controlled electronically with two switches placed in the autosampler, which are activated when the autosampler arm is down. Thus, the process is fully automated without any modification of the software of the atomic absorption spectrometer. Under the optimum conditions with a 60-s preconcentration time, a sample flow rate of 2.4 mL min(-1), and an injection volume of eluent of 40 microL, a linear calibration graph was obtained in the range 0-100 ng mL(-1). The enrichment factor was 14. The detection limit under these conditions is 1 ng mL(-1), and the relative standard deviation (RSD) is 1.6% for 10 ng mL(-1) of Pt. The method has been applied to the determination of platinum in catalyst, vegetation, soil, and natural water samples. The results showed good agreement with the certified value and the recoveries of Pt added to samples were 98-105%.


Related Compounds

  • dowex 1x4-200 ion-...

Related Articles:

On-line preconcentration of mercury by sorption on an anion-exchange resin loaded with 1,5-bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide and determination by cold-vapour inductively coupled plasma atomic emission.

1998-08-01

[Talanta 46 , 1095-1105, (1998)]

On-line preconcentration of rhodium on an anion-exchange resin loaded with 1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydrazide and its determination in environmental samples.

2004-09-08

[Talanta 64 , 230-236, (2004)]

Synthesis of new hypoxia markers EF1 and [18F]-EF1.

1999-12-01

[Appl. Radiat. Isot. 51(6) , 643-50, (1999)]

Borate complexes of x-ray iodinated contrast agents: characterization and sorption studies for their removal from aqueous media.

2012-02-29

[J. Hazard. Mater. 205-206 , 10-16, (2012)]

Apolipoprotein E isoform-specific disruption of phosphoinositide hydrolysis: protection by estrogen and glutathione.

2001-08-24

[FEBS Lett. 504(1-2) , 45-9, (2001)]

More Articles...