Journal of Pharmaceutical and Biomedical Analysis 2002-10-15

In vitro study of enzymatic hydrolysis of diperodon enantiomers in blood serum by two-dimensional LC.

K Hrobonová, J Lehotay, J Cizmárik, D W Armstrong

Index: J. Pharm. Biomed. Anal. 30(3) , 875-80, (2002)

Full Text: HTML

Abstract

An on-line coupled HPLC system is described for the determination of the enantiomers of diperodon in blood serum. The method involves three steps: (i) off-line preconcentration and clean-up, (ii) separation of the diperodon enantiomers from the matrix components on a reversed-phase stationary phase, and (iii) separation of the racemate from the reversed-phase column on a teicoplanin chiral stationary phase. The method is suitable for simultaneous determination of both enantiomers in serum up to 0.5 microg/ml. The degradation of diperodon enantiomers was studied in serum by an in vitro method and the experimental rate constants were determined. The enantiomeric hydrolysis rates and half-lives for diperodon in serum are different.Copyright 2002 Elsevier Science B.V.


Related Compounds

  • Diperodon (hydroch...

Related Articles:

Study of local anaesthetics. Part 133. Determination of diperodon in blood serum in vitro by the HPLC method.

1996-01-01

[Acta Pol. Pharm. 53(3) , 167-9, (1996)]

[HPLC determination of diperodon enantiomers in blood serum by using teicoplanin chiral stationary phase].

2004-09-01

[Ceska. Slov. Farm. 53(5) , 225-7, (2004)]

Allergy to the local anaesthetic diperodon.

1980-08-01

[Contact Dermatitis 6(5) , 367, (1980)]