Sibiromycin
Suppliers
Names
Chemical & Physical Properties
[ Density]:
1.41g/cm3
[ Boiling Point ]:
755.7ºC at 760 mmHg
[ Molecular Formula ]:
C24H31N3O7
[ Molecular Weight ]:
473.51900
[ Flash Point ]:
410.8ºC
[ Exact Mass ]:
473.21600
[ PSA ]:
145.44000
[ LogP ]:
1.99250
[ Vapour Pressure ]:
5.32E-24mmHg at 25°C
[ Index of Refraction ]:
1.662
Toxicological Information
CHEMICAL IDENTIFICATION
- RTECS NUMBER :
- UY8495000
- CHEMICAL NAME :
- 5H-Pyrrolo(2,1-c)(1,4)benzodiazepin-5-one, 7-((4,6-dideoxy-3-(methyl-4-(methylamino)-beta- D-altropyranosyl)oxy))-10,11-dihydro-9,11-dihydroxy-8 -methyl-2-(1-propenyl )-
- CAS REGISTRY NUMBER :
- 12684-33-2
- LAST UPDATED :
- 199609
- DATA ITEMS CITED :
- 13
- MOLECULAR FORMULA :
- C24-H31-N3-O7
- MOLECULAR WEIGHT :
- 473.58
- WISWESSER LINE NOTATION :
- T C576 BVN IM HHJ E1U2 HQ KQ L1 MO- BT6OTJ CQ DQ D1 EM1 F1
HEALTH HAZARD DATA
ACUTE TOXICITY DATA
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Intraperitoneal
- SPECIES OBSERVED :
- Rodent - rat
- DOSE/DURATION :
- 6 ug/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Rodent - rat
- DOSE/DURATION :
- 29 ug/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Oral
- SPECIES OBSERVED :
- Rodent - mouse
- DOSE/DURATION :
- 459 ug/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Intraperitoneal
- SPECIES OBSERVED :
- Rodent - mouse
- DOSE/DURATION :
- 32 ug/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Subcutaneous
- SPECIES OBSERVED :
- Rodent - mouse
- DOSE/DURATION :
- 84 ug/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Rodent - mouse
- DOSE/DURATION :
- 58 ug/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- TYPE OF TEST :
- LD10 - Lethal Dose
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Mammal - dog
- DOSE/DURATION :
- 5 ug/kg
- TOXIC EFFECTS :
- Cardiac - pericarditis Cardiac - other changes
- TYPE OF TEST :
- LD10 - Lethal Dose
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Rodent - rabbit
- DOSE/DURATION :
- 12 ug/kg
- TOXIC EFFECTS :
- Blood - other changes
- TYPE OF TEST :
- TDLo - Lowest published toxic dose
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Rodent - mouse
- DOSE/DURATION :
- 98 ug/kg/4D-I
- TOXIC EFFECTS :
- Related to Chronic Data - death
- TYPE OF TEST :
- TDLo - Lowest published toxic dose
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Mammal - dog
- DOSE/DURATION :
- 22500 ng/kg/30D-I
- TOXIC EFFECTS :
- Cardiac - cardiomyopathy including infarction Blood - changes in serum composition (e.g. TP, bilirubin, cholesterol) Biochemical - Enzyme inhibition, induction, or change in blood or tissue levels - transaminases
- TYPE OF TEST :
- TDLo - Lowest published toxic dose
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Rodent - rabbit
- DOSE/DURATION :
- 30 ug/kg/15D-I
- TOXIC EFFECTS :
- Kidney, Ureter, Bladder - other changes Blood - changes in serum composition (e.g. TP, bilirubin, cholesterol) Related to Chronic Data - death
MUTATION DATA
- TYPE OF TEST :
- Mutation test systems - not otherwise specified
- TEST SYSTEM :
- Rodent - mouse Ascites tumor
- DOSE/DURATION :
- 1 ug/L
- REFERENCE :
- NEOLA4 Neoplasma. (Karger-Libri, P.O. Box, CH-4009 Basel, Switzerland) V.4- 1957- Volume(issue)/page/year: 22,105,1975
Related Compounds
The content on this webpage is sourced from various professional data sources. If you have any questions or concerns regarding the content, please feel free to contact service1@chemsrc.com.