Cupric acetylacetonate
Suppliers
Names
[ CAS No. ]:
13395-16-9
[ Name ]:
Cupric acetylacetonate
[Synonym ]:
3-Penten-2-one, 4-hydroxy-, copper(2+) salt, (3Z)- (2:1)
Copper(2+) bis[(2Z)-4-oxopent-2-en-2-olate]
Cupric(II) acetylacetonate
2,4-Pentanedione copper(II) derivative (Bis(2,4-pentanedionato)copper(II)
Copper(2+) bis[(2Z)-4-oxo-2-penten-2-olate]
Copper(II) Acetylacetonate
Copper(II) 4-oxopent-2-en-2-olate
EINECS 236-477-9
Bis(2,4-pentanedionato)copper(II)
Bis(acetylacetone)copper
Copper acetylacetonate
2,4-Pentanedione copper(II) derivative
MFCD00000016
Cupric Acetylacetonate
Acetylacetone Copper(II) Salt
Chemical & Physical Properties
[ Boiling Point ]:
160ºC (9.8 mmHg)
[ Melting Point ]:
245ºC
[ Molecular Formula ]:
C10H14CuO4
[ Molecular Weight ]:
261.762
[ Flash Point ]:
160°C/10mm
[ Exact Mass ]:
261.018799
[ PSA ]:
52.60000
[ LogP ]:
1.91770
[ Water Solubility ]:
0.2 g/L (20 ºC)
MSDS
Toxicological Information
CHEMICAL IDENTIFICATION
- RTECS NUMBER :
- GL6520000
- CHEMICAL NAME :
- Copper, bis(2,4-pentanedionato)-
- CAS REGISTRY NUMBER :
- 13395-16-9
- LAST UPDATED :
- 199701
- DATA ITEMS CITED :
- 4
- MOLECULAR FORMULA :
- C10-H14-Cu-O4
- MOLECULAR WEIGHT :
- 261.78
- WISWESSER LINE NOTATION :
- 1VYV1&-CU-YV1&V1
HEALTH HAZARD DATA
ACUTE TOXICITY DATA
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Intraperitoneal
- SPECIES OBSERVED :
- Rodent - mouse
- DOSE/DURATION :
- 19 mg/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- REFERENCE :
- CHTHBK Chemotherapy (Basel). (S. Karger Pub., Inc., 79 Fifth Ave., New York, NY 10003) V.13- 1968- Volume(issue)/page/year: 16,371,1971
- TYPE OF TEST :
- LD50 - Lethal dose, 50 percent kill
- ROUTE OF EXPOSURE :
- Intravenous
- SPECIES OBSERVED :
- Rodent - mouse
- DOSE/DURATION :
- 10 mg/kg
- TOXIC EFFECTS :
- Details of toxic effects not reported other than lethal dose value
- REFERENCE :
- CSLNX* U.S. Army Armament Research & Development Command, Chemical Systems Laboratory, NIOSH Exchange Chemicals. (Aberdeen Proving Ground, MD 21010) Volume(issue)/page/year: NX#00604 *** NIOSH STANDARDS DEVELOPMENT AND SURVEILLANCE DATA *** NIOSH OCCUPATIONAL EXPOSURE SURVEY DATA : NOES - National Occupational Exposure Survey (1983) NOES Hazard Code - X2730 No. of Facilities: 1041 (estimated) No. of Industries: 11 No. of Occupations: 13 No. of Employees: 8588 (estimated) No. of Female Employees: 1749 (estimated)
Safety Information
[ Symbol ]:
GHS07
[ Signal Word ]:
Warning
[ Hazard Statements ]:
H315-H319-H335
[ Precautionary Statements ]:
P261-P305 + P351 + P338
[ Personal Protective Equipment ]:
dust mask type N95 (US);Eyeshields;Gloves
[ Hazard Codes ]:
Xn:Harmful;
[ Risk Phrases ]:
R20/21/22;R36/37/38
[ Safety Phrases ]:
S26-S36/37/39
[ RIDADR ]:
NONH for all modes of transport
[ WGK Germany ]:
3
[ RTECS ]:
GL6520000
[ HS Code ]:
29420000
Synthetic Route
Precursor & DownStream
Precursor
DownStream
Customs
[ HS Code ]: 29420000
Articles
J. Orthop. Res. 32(5) , 727-34, (2014)
This study evaluated the efficacy of using calcium sulfate (CaSO4 ) as a carrier for intramedullary delivery of an organic vanadium salt, vanadyl acetylacetonate (VAC) after femoral fracture. VAC can ...
Brachytherapy 12(2) , 171-7, (2013)
Holmium-166 acetylacetonate microspheres ((166)Ho-AcAc-MS) are proposed as an intratumoral radioablation device. This article presents a pilot study in housecats with unresectable liver cancer. Feasib...
Analyst 136(10) , 2151-5, (2011)
Though recently Ir(III) complexes have attracted much interest in electrochemiluminescent (ECL) analysis due to their high emission in various wavelengths, there were a few studies reported on its ana...