Journal of chromatography. A 2014-10-03

Evaluation of quadrupole-time-of-flight mass spectrometry in comprehensive two-dimensional gas chromatography.

Blagoj Mitrevski, Philip J Marriott

文献索引:J. Chromatogr. A. 1362 , 262-9, (2014)

全文:HTML全文

摘要

Quadrupole time-of-flight mass spectrometry (Q-TOFMS) has been evaluated with respect to its applicability in comprehensive two-dimensional gas chromatography (GC×GC). At a maximum acquisition frequency, while approximately 50 full accurate mass spectra on disk were acquired per s (50Hz) in scan mode, the sampling rate in target mode (MS/MS) was strongly dependent on the number of target ions selected. The number of selected precursor ions per time window proportionally decreased the acquisition rate for each ion; one precursor ion ≅31.35Hz; two ions ≅16.68Hz; and for 8 precursor ions, a sampling rate of just 4.18Hz was found. When Q-TOFMS was used in simultaneous mode, where in addition to the acquisition of target ion MS/MS signals, it also collects the full mass spectrum, sampling rates were even lower. It is demonstrated that Q-TOFMS generates sufficient data points over each peak in GC×GC operation in scan mode using TOFMS acquisition only, or is able to collect sufficient data points for relatively wide chromatographic peaks (≥600ms) in the target mode (MS/MS), however only if one or two precursor ions are selected per time window. Mass accuracy was found to perform within specification (<5ppm), even for the fastest acquisition operation (50Hz). Spectral deconvolution is demonstrated to work better in GC×GC than in 1D GC mode. Data visualisation in target GC×GC mode presents difficulties when there are overlapping target windows comprising different numbers of precursor ions. Copyright © 2014 Elsevier B.V. All rights reserved.


相关化合物

  • 磷酸三苯酯
  • 丙酮
  • 二环己胺
  • 磷酸三丁酯

相关文献:

Multi-contaminant analysis of organophosphate and halogenated flame retardants in food matrices using ultrasonication and vacuum assisted extraction, multi-stage cleanup and gas chromatography-mass spectrometry.

2015-07-03

[J. Chromatogr. A. 1401 , 33-41, (2015)]

Magnetic graphene as modified quick, easy, cheap, effective, rugged and safe adsorbent for the determination of organochlorine pesticide residues in tobacco.

2015-08-07

[J. Chromatogr. A. 1406 , 1-9, (2015)]

Magnetic "one-step" quick, easy, cheap, effective, rugged and safe method for the fast determination of pesticide residues in freshly squeezed juice.

2015-06-12

[J. Chromatogr. A. 1398 , 1-10, (2015)]

[Resistance mechanisms of Spodoptera exigua (Hübner) to fenvalerate and alpha-cypermethrin].

2010-01-01

[Ying Yong Sheng Tai Xue Bao 21(1) , 203-8, (2010)]

Mechanisms of organophosphate resistance in a field population of oriental migratory locust, Locusta migratoria manilensis (Meyen).

2009-05-01

[Arch. Insect Biochem. Physiol. 71(1) , 3-15, (2009)]

更多文献...