The European journal of prosthodontics and restorative dentistry 2013-06-01

The effect of denture design and fixatives on the retention of mandibular complete dentures tested on a novel in-vitro edentulous model.

A Johnson, N Al-Kaisy, C A Miller, N Martin

文献索引:Eur. J. Prosthodont. Restor. Dent. 21(2) , 64-74, (2013)

全文:HTML全文

摘要

The aim of this study was to evaluate the effect of the design (extension and adaptation) of a mandibular complete acrylic denture and the use of denture adhesives using a novel in-vitro edentulous model. The model is a highly anatomically accurate replica based on a moderately resorbed human mandibular edentulous arch. The model has been designed and fabricated by means of an elaborate clinical and technical process that employs synthetic elastomeric materials with properties that attempts to reproduce in-vitro characteristics of the soft tissues overlying the ridges and immediate reflected tissues. This model was used to measure and compare the retention of mandibular dentures ofvarying designs (well-fitting, over- and under-extended) with and without the aid of denture fixatives. Retention tests were conducted with different volumes of artificial saliva at a cross head speed of 50 mm/min with 4 equidistant holding points on the denture occlusal surface, using a universal tensile testing machine in an axial pull direction. The effect of three denture adhesives on denture retention was also tested on the same denture types at different times over a period of 5 hours and beyond. The in-vitro model presented can be effectively used to test the retention of mandibular complete dentures. The speed of dislodgement force and amount of saliva are important variables in mandibular denture retention. The retention of well-fitting dentures was statistically higher than that of ill-fitting dentures. A significantly higher retention force was needed to dislodge mandibular dentures (well and ill-fitting dentures) when using a denture adhesive.


相关化合物

  • 甲基乙烯基醚-马来...
  • 硫酸钙 半水合物
  • 硫酸钙,二水合物
  • 无水硫酸钙
  • 羧甲基纤维素钠

相关文献:

Capture of infectious borna disease virus using anionic polymer-coated magnetic beads.

2011-05-02

[Neurosci. Lett. 494(3) , 237-9, (2011)]

The response of subcutaneous connective tissue to newly developed calcium phosphate-based root canal sealers.

2011-04-01

[Int. Endod. J. 44(4) , 342-52, (2011)]

Assessment of hypersensitivity reduction of a dentifrice containing 0.3% triclosan, 2.0% PVM/MA copolymer, 0.243% NaF and specially-designed silica as compared to a dentifrice containing 0.454% stannous fluoride, sodium hexametaphosphate and zinc lactate and to a dentifrice containing 0.243% NaF on dentin hypersensitivity reduction: an 8-week study.

2011-07-01

[Am. J. Dent. 24 Spec No A , 14A-20A, (2011)]

Synthesis of microwave-assisted poly(methyl vinyl ether-co-maleic anhydride)-bovine serum albumin bioconjugates.

2012-12-01

[Artif. Cells Blood Substit. Immobil. Biotechnol. 40(6) , 363-8, (2012)]

Comparative investigation of a dentifrice containing triclosan/copolymer/sodium fluoride and specially-designed silica and a dentifrice containing 0.243% sodium fluoride in a silica base for the control of established supra-gingival plaque and gingivitis: a 6-month clinical study.

2011-07-01

[Am. J. Dent. 24 Spec No A , 21A-27A, (2011)]

更多文献...