Analytical and Bioanalytical Chemistry 2015-06-01

Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography.

María Cordero-Vaca, María J Trujillo-Rodríguez, Cheng Zhang, Verónica Pino, Jared L Anderson, Ana M Afonso

文献索引:Anal. Bioanal. Chem 407 , 4615-27, (2015)

全文:HTML全文

摘要

Four different crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were evaluated in an automated direct-immersion solid-phase microextraction method (automated DI-SPME) in combination with gas chromatography (GC). The crosslinked PIL coatings were based on vinyl-alkylimidazolium- (ViCnIm-) or vinylbenzyl-alkylimidazolium- (ViBzCnIm-) IL monomers, and di-(vinylimidazolium)dodecane ((ViIm)2C12-) or di-(vinylbenzylimidazolium)dodecane ((ViBzIm)2C12-) dicationic IL crosslinkers. In addition, a PIL-based hybrid coating containing multi-walled carbon nanotubes (MWCNTs) was also studied. The studied PIL coatings were covalently attached to derivatized nitinol wires and mounted onto the Supelco assembly to ensure automation when acting as SPME coatings. Their behavior was evaluated in the determination of a group of water pollutants, after proper optimization. A comparison was carried out with three common commercial SPME fibers. It was observed that those PILs containing a benzyl group in their structures, either in the IL monomer and crosslinker (PIL-1-1) or only in the crosslinker (PIL-0-1), were the most efficient sorbents for the selected analytes. The validation of the overall automated DI-SPME-GC-flame ionization detector (FID) method gave limits of detection down to 135 μg · L(-1) for p-cresol when using the PIL-1-1 and down to 270 μg · L(-1) when using the PIL-0-1; despite their coating thickness: ~2 and ~5 μm, respectively. Average relative recoveries with waters were of 85 ± 14 % and 87 ± 15 % for PIL-1-1 and PIL-0-1, respectively. Precision values as relative standard deviation were always lower than 4.9 and 7.6 % (spiked level between 10 and 750 μg · L(-1), as intra-day precision). Graphical Abstract Automated DI-SPME-GC-FID using crosslinked-PILs sorbent coatings for the determination of waterpollutants.


相关化合物

  • 八甲基三硅氧烷
  • 氢氧化钠
  • 咪唑
  • 偶氮二异丁腈
  • 六甲基二硅氧烷
  • 乙腈
  • 过氧化氢
  • 异丙醇
  • 乙烯基三甲氧基硅烷
  • 3-乙基-2,4-戊烷二...

相关文献:

A novel pathway producing dimethylsulphide in bacteria is widespread in soil environments.

2015-01-01

[Nat. Commun. 6 , 6579, (2015)]

Microfluidics-based in situ padlock/rolling circle amplification system for counting single DNA molecules in a cell.

2014-01-01

[Anal. Sci. 30(12) , 1107-12, (2014)]

Combined effects of drying methods, extract concentration, and film thickness on efficacy of antimicrobial chitosan films.

2014-06-01

[J. Food Sci. 79(6) , E1150-8, (2014)]

A salting out system for improving the efficiency of the headspace solid-phase microextraction of short and medium chain free fatty acids.

2015-08-28

[J. Chromatogr. A. 1409 , 282-7, (2015)]

Olfactometry Profiles and Quantitation of Volatile Sulfur Compounds of Swiss Tilsit Cheeses.

2015-09-02

[J. Agric. Food Chem. 63 , 7511-21, (2015)]

更多文献...