Pharmazie 2014-07-01

Development of a novel triamcinolone acetonide-loaded spray solution for the treatment of stomatitis.

Dong Wuk Kim, Yong-Il Kim, Fakhar Ud Din, Kwan Hyung Cho, Jong Oh Kim, Han-Gon Choi

文献索引:Pharmazie 69(7) , 512-7, (2014)

全文:HTML全文

摘要

To develop a novel triamcinolone acetonide (TAA)-loaded spray for the treatment of stomatitis, several spray solutions were prepared using various amounts of TAA, Eudragit L100 (Eudragit L) and PEG 400, and 100 ml ethanol. Their viscosity and spraying potential were investigated, with the result that the spraying threshold was 9.5 cP. The effect of PEG 400 on the properties of films formed after spraying was assessed. Its anti-inflammatory effect in mice was evaluated and compared to a commercial product. As the PEG 400 concentration increased, the film elongation and washability by the saliva solution increased, and tensile strength decreased. PEG 400 had little effect on mucoadhesive force and drug release. The TAA-loaded spray solution containing TAA, Eudragit L, PEG 400 and ethanol at the ratio of 1:6:3:100 (w/w/w/v) was easy to spray onto stomatitis lesions in the mouth via a spraying vessel incorporating a long straw. After spraying, the TAA-loaded spray formed a film with suitable elongation, tensile strength and washability that attached onto the mucosal membrane and released the drug. Moreover, it had excellent anti-inflammatory properties, similar to those of the commercial product. Thus, this novel TAA-loaded spray solution was easy to administer, had good film properties and excellent anti-inflammatory efficacy, and is therefore a potential candidate for the treatment of stomatitis.


相关化合物

  • 曲安奈德
  • 2-甲基-2-丙烯酸的...

相关文献:

Novel Nrf2 activators from microbial transformation products inhibit blood-retinal barrier permeability in rabbits.

2015-03-01

[Br. J. Pharmacol. 172(5) , 1237-49, (2015)]

Evaluation of the reporting level to detect triamcinolone acetonide misuse in sports.

2015-01-01

[J. Steroid Biochem. Mol. Biol. 145 , 94-102, (2015)]

A general analytical platform and strategy in search for illegal drugs.

2014-11-01

[J. Pharm. Biomed. Anal. 100 , 215-29, (2014)]

Detection and characterization of triamcinolone acetonide metabolites in human urine by liquid chromatography/tandem mass spectrometry after intramuscular administration.

2014-08-30

[Rapid Commun. Mass Spectrom. 28(16) , 1829-39, (2015)]

Verteporfin therapy and triamcinolone acetonide: convergent modes of action for treatment of neovascular age-related macular degeneration.

2006-01-01

[Eur. J. Ophthalmol. 16(6) , 824-34, (2006)]

更多文献...