Journal of chromatography. A 2015-02-27

Efficiency of short, small-diameter columns for reversed-phase liquid chromatography under practical operating conditions.

Yan Ma, Alexander W Chassy, Shota Miyazaki, Masanori Motokawa, Kei Morisato, Hideyuki Uzu, Masayoshi Ohira, Masahiro Furuno, Kazuki Nakanishi, Hiroyoshi Minakuchi, Khaled Mriziq, Tivadar Farkas, Oliver Fiehn, Nobuo Tanaka

文献索引:J. Chromatogr. A. 1383 , 47-57, (2015)

全文:HTML全文

摘要

Prototype small-size (1.0mm I.D., 5cm long) columns for reversed-phase HPLC were evaluated in relation to instrument requirements. The performance of three types of columns, monolithic silica and particulate silica (2μm, totally porous and 2.6μm, core-shell particles) was studied in the presence of considerable or minimal extra-column effects, while the detector contribution to band broadening was minimized by employing a small size UV-detector cell (6- or 90nL). A micro-LC instrument having small system volume (<1μL) provided extra-column band variance of only 0.01-0.02μL(2). The three columns generated about 8500 theoretical plates for solutes with retention factor, k>1-3 (depending on the column), in acetonitrile/water mobile phase (65/35=vol/vol) at 0.05mL/min, with the instrument specified above. The column efficiency was lower by up to 30% than that observed with a 2.1mm I.D. commercial column. The small-size columns also provided 8000-8500 theoretical plates for well retained solutes with a commercial ultrahigh-pressure liquid chromatography (UHPLC) instrument when extra-column contributions were minimized. While a significant extra-column effect was observed for early eluting solutes (k<2-4, depending on column) with methanol/water (20/80=vol/vol) as weak-wash solvent, the use of methanol/water=50/50 as wash solvent affected the column efficiency for most analytes. The results suggest that the band compression effect by the weak-wash solvent associated with partial-loop injection may provide a practical means to reducing the extra-column effect for small-size columns, while the use of an instrument with minimum extra-column effect is highly desirable. Copyright © 2015 Elsevier B.V. All rights reserved.


相关化合物

  • 二苯甲酮
  • 苯乙酮
  • 乙腈
  • N-乙酰苯胺
  • 莠灭净
  • 西玛津
  • 扑灭津
  • 苯丙酮
  • 苯丁酮
  • 硫脲

相关文献:

Layered titanium diboride: towards exfoliation and electrochemical applications.

2015-08-07

[Nanoscale 7 , 12527-34, (2015)]

Probing multivalency in ligand-receptor-mediated adhesion of soft, biomimetic interfaces.

2015-01-01

[Beilstein J. Org. Chem. 11 , 720-9, (2015)]

Gas chromatography with parallel hard and soft ionization mass spectrometry.

2015-01-15

[Rapid Commun. Mass Spectrom. 29(1) , 91-9, (2014)]

Degradation of anti-inflammatory drug ketoprofen by electro-oxidation: comparison of electro-Fenton and anodic oxidation processes.

2014-01-01

[Environ. Sci. Pollut. Res. Int. 21(14) , 8406-16, (2014)]

Biomedical Activity and Related Volatile Compounds of Thai Honeys from 3 Different Honeybee Species.

2015-10-01

[J. Food Sci. 80 , M2228-40, (2015)]

更多文献...