Validation of a method for the simultaneous quantification of chloroquine, desethylchloroquine and primaquine in plasma by HPLC-DAD
Lina Zuluaga-Idárraga, Natalia Yepes-Jiménez, Carlos López-Córdoba, Silvia Blair-Trujillo
文献索引:J. Pharm. Biomed. Anal. 95 , 200-6, (2014)
全文:HTML全文
摘要
• Chloroquine, desethyl chloroquine and primaquine level were quantified simultaneously by HPLC-DAD. • The method validation parameters were adequate according international standards. • Sample preparation procedure is easy and inexpensive. • The method was successfully applied to plasma patient samples. • The method is suitable to carry out therapeutic efficacy studies.
相关化合物
相关文献:
2015-04-13
[Biomacromolecules 16(4) , 1382-9, (2015)]
2014-10-01
[J. Comp. Physiol. B, Biochem. Syst. Environ. Physiol. 184(7) , 865-76, (2014)]
2014-12-08
[Biomacromolecules 15(12) , 4561-9, (2014)]
2014-08-07
[Nanoscale 6(15) , 8720-5, (2014)]
2014-01-01
[PeerJ 2 , e284, (2014)]