Nephrology Dialysis Transplantation 2009-05-01

Development of an affordable dye-stained microalbuminuria screening test.

Pierrot Lundimu Tugirimana, Joris R Delanghe

文献索引:Nephrol. Dial. Transplant. 24(5) , 1485-90, (2009)

全文:HTML全文

摘要

A simple spot test was developed, which allows quantification of microalbuminuria. Evaluation was carried out according to the ISO 15189 guidelines.Urine was spotted on cellulose acetate strips and stained using different sensitive protein binding dyes (nigrosin, Coomassie Blue R-250, amido black). The colour intensity of the stained spots was quantified using a Kodak Image 450 station.Analytical sensitivity of the Coomassie Blue based method (18 mg/L) was better than that for nigrosin (50 mg/ L) or amido black (100 mg/L) based methods. Within-run coefficient of variation (CV) and between-run CV of the Coomassie blue assay were, respectively, 8.4% and 9.7% (50 mg/L), and 3% and 4.5% (400 mg/L). For nigrosin, these data were, respectively, 8.4 and 9.4 (50 mg/L), and 3.4 and 6.4% (400 mg/L). Coomassie Blue showed a preferential binding selectivity towards albumin. The method was found to be linear between 20 and 600 mg/L. A good correlation (r2 = 0.89) was obtained between Coomassie Blue based and immunonephelometric measurements. Immuno-unreactive albumin (prepared by protease treatment) could be detected by the spot test, which offers an advantage of the method versus immunochemical tests. Ammonium sulphate precipitation could further increase the specificity of the assay by eliminating effects of free light chains.The described method is very simple and extremely cheap, which makes it potentially suited for screening programmes, particularly in third world countries.


相关化合物

  • 氨基黑10B
  • 黑色素(水溶)
  • 考马斯亮蓝R250

相关文献:

Liquid chromatography tandem mass spectrometry analysis of photodegradation of a diazo compound: a mechanistic study.

2010-06-01

[Chemosphere 80(4) , 422-7, (2010)]

Ability to use the diazo dye, C.I. Acid Black 1 as a nitrogen source by the marine cyanobacterium Oscillatoria curviceps BDU92191

2011-07-01

[Bioresour. Technol. 102(14) , 7218-23, (2011)]

The use of total protein stains as loading controls: An alternative to high-abundance single-protein controls in semi-quantitative immunoblotting

2008-01-01

[J. Neurosci. Methods 172 , 250-254, (2008)]

Quantification of surface-bound proteins by fluorometric assay: Comparison with quartz crystal microbalance and amido black assay.

2006-10-19

[J. Phys. Chem. B 110(41) , 20572-9, (2006)]

A cadaver study to determine the minimum volume of methylene blue or black naphthol required to completely color the nerves relevant for anesthesia during breast surgery.

2011-03-01

[Clin. Anat. 24(2) , 202-8, (2011)]

更多文献...