A luminescence-based probe for sensitive detection of hydrogen peroxide in seconds.
Kristin Zscharnack, Thomas Kreisig, Agneta A Prasse, Thole Zuchner
文献索引:Anal. Chim. Acta 834 , 51-7, (2014)
全文:HTML全文
摘要
Here, we present a fast and simple hydrogen peroxide assay that is based on time-resolved fluorescence. The emission intensity of a complex consisting of terbium ions (Tb(3+)) and phthalic acid (PA) in HEPES buffer is quenched in the presence of H2O2 and this quenching is concentration-dependent. The novel PATb assay detects hydrogen peroxide at a pH range from 7.5 to 8.5 and with a detection limit of 150 nmol L(-1) at pH 8.5. The total assay time is less than 1 min. The linear range of the assay can be adapted by a pH adjustment of the aqueous buffer and covers a concentration range from 310 nmol L(-1) to 2.56 mmol L(-1) in total which encompasses four orders of magnitude. The assay is compatible with high concentrations of all 47 tested inorganic and organic compounds. The PATb assay was applied to quantify H2O2 in polluted river water samples. In conclusion, this fast and easy-to-use assay detects H2O2 with high sensitivity and precision.Copyright © 2014 Elsevier B.V. All rights reserved.
相关化合物
相关文献:
2015-04-01
[Acta Physiol. (Oxf.) 213(4) , 902-19, (2015)]
2015-02-11
[J. Neurosci. 35(6) , 2384-97, (2015)]
2014-09-01
[PLoS Genet. 10(9) , e1004659, (2014)]
2014-12-01
[Tissue Eng. Part A 20(23-24) , 3163-75, (2014)]
2015-01-01