摘要

Coagulation with the conventional coagulants such as ferric and aluminum salts is not efficient for As(III) removal. In this study Ti(SO4)2 was employed for enhanced As(III) removal and Fe2(SO4)3 was used as a reference. The removal efficiencies of As(III) by Ti(SO4)2 at pH 4.0-9.0 were greater than that by Fe2(SO4)3 by 7.39-32.8% and 3.14-48.1% for coagulants dosed at 8.0 mg/L and 12.0 mg/L, respectively. The advantage of Ti(SO4)2 over Fe2(SO4)3 for As(III) removal was more significant at lower pH, which may be ascribed to the more negatively charged surface of Ti(IV) hydroxides. To reduce As(III) from 0.2 mg/L to 10 μg/L, the necessary dosage of Ti(SO4)2 was only ≈ 50% of that of Fe2(SO4)3. The adsorption capacity of As(III) on Ti(IV) hydroxides formed in-situ was greater than that on Fe(III) hydroxides formed in-situ by ≈ 100 mg/g and several times higher than the adsorption capacities of TiO2 for As(III) reported in the literature. The presence of competing anions, silicate, phosphate and humic acid, did not alter the advantage of Ti(SO4)2 over Fe2(SO4)3 for arsenite removal. Replacing partial Ti(SO4)2 with Fe2(SO4)3 (same dosage) and applying them sequentially could achieve similar As(III) removal efficiency as single Ti(SO4)2, which could thus reduce the chemical cost. The extended X-ray absorption fine structure (EXAFS) spectroscopy indicated that As(III) form bidentate binuclear surface complexes with Ti(IV) hydroxides as evidenced by As(III)-Ti bond distances of 3.33-3.35 Å. This study revealed that Ti(SO4)2 may be an alternative coagulant for efficient As(III) removal.Copyright © 2013 Elsevier Ltd. All rights reserved.


相关化合物

  • 金属锶
  • 硫酸铁(Ⅱ)铵分析滴...

相关文献:

Tracking mobility using human hair: What can we learn from lead and strontium isotopes?

2015-01-01

[Sci. Justice 55(1) , 63-71, (2015)]

Analysis of radium-226 in high salinity wastewater from unconventional gas extraction by inductively coupled plasma-mass spectrometry.

2015-03-03

[Environ. Sci. Technol. 49(5) , 2969-76, (2015)]

Diagnostic use of cerebral and extracerebral oxysterols.

2004-02-01

[Clin. Chem. Lab Med. 42(2) , 186-91, (2004)]

Levels of 7-oxocholesterol in cerebrospinal fluid are more than one thousand times lower than reported in multiple sclerosis.

2005-02-01

[J. Lipid Res. 46(2) , 191-5, (2005)]

Disruption of thiol homeostasis and nitrosative stress in the cerebrospinal fluid of patients with active multiple sclerosis: evidence for a protective role of acetylcarnitine.

2003-09-01

[Neurochem. Res. 28(9) , 1321-8, (2003)]

更多文献...