Journal of chromatography. A 2015-08-28

Effect of gradient steepness on the kinetic performance limits and peak compression for reversed-phase gradient separations of small molecules.

Nikola Vaňková, Jelle De Vos, Eva Tyteca, Gert Desmet, Tony Edge, Lenka Česlová, Petr Česla, Sebastiaan Eeltink

文献索引:J. Chromatogr. A. 1409 , 152-8, (2015)

全文:HTML全文

摘要

The effect of gradient steepness on the kinetic performance limits and peak compression effects has been assessed in gradient mode for the separation of phenol derivatives using columns packed with 2.6μm core-shell particles. The effect of mobile-phase velocity on peak capacity was measured on a column with fixed length while maintaining the retention factor at the moment of elution and the peak-compression factor constant. Next, the performance limits were determined at the maximum system pressure of 100MPa while varying the gradient steepness. For the separation of small molecules applying a linear gradient with a broad span, the best performance limits in terms of peak capacity and analysis time were obtained applying a gradient-time-to-column-dead-time (tG/t0) ratio of 12. The magnitude of the peak-compression factor was assessed by comparing the isocratic performance with that in gradient mode applying different gradient times. Therefore, the retention factors for different analytes were determined in gradient mode and the mobile-phase composition in isocratic mode was tuned such that the difference in retention factor was smaller than 2%. Peak-compression factors were quantitatively determined between 0.95 and 0.65 depending on gradient steepness and the gradient retention factor. Copyright © 2015 Elsevier B.V. All rights reserved.


相关化合物

  • N-乙酰苯胺
  • 苯丁酮
  • 邻甲酚
  • 苯庚酮
  • 苯丙酮
  • 2-氨基-5-硝基苯酚
  • 苯己酮
  • 苯乙酮
  • 邻硝基苯酚
  • 4-溴-2,6-二甲基苯...

相关文献:

Convenient QSAR model for predicting the complexation of structurally diverse compounds with β-cyclodextrins

2009-01-01

[Bioorg. Med. Chem. 17 , 896-904, (2009)]

Calculating virtual log P in the alkane/water system (log P(N)(alk)) and its derived parameters deltalog P(N)(oct-alk) and log D(pH)(alk).

2005-05-05

[J. Med. Chem. 48 , 3269-79, (2005)]

Optimization of a large-volume injection method for compound-specific isotope analysis of polycyclic aromatic compounds at trace concentrations.

2015-12-30

[Rapid Commun. Mass Spectrom. 29 , 2349-60, (2015)]

A comprehensive platform to investigate protein-metal ion interactions by affinity capillary electrophoresis.

2015-03-25

[J. Pharm. Biomed. Anal. 107 , 311-7, (2015)]

Efficiency of short, small-diameter columns for reversed-phase liquid chromatography under practical operating conditions.

2015-02-27

[J. Chromatogr. A. 1383 , 47-57, (2015)]

更多文献...