Therapeutic Drug Monitoring 2016-02-01

Determination of Common Antipsychotics in Quantisal-Collected Oral Fluid by UHPLC-MS/MS: Method Validation and Applicability for Therapeutic Drug Monitoring.

Lisbeth Patteet, Kristof E Maudens, Manuel Morrens, Bernard Sabbe, Geert Dom, Hugo Neels

文献索引:Ther. Drug Monit. 38 , 87-97, (2016)

全文:HTML全文

摘要

Oral fluid (OF) is an interesting alternative for conventional blood testing in therapeutic drug monitoring. OF can be used for screening but its value for quantification has to be established.To evaluate the value of OF for quantification of 11 commonly used antipsychotics (APs) and 5 metabolites, an ultra-high performance liquid chromatography-tandem mass spectrometric method was validated. OF was obtained from psychiatric patients using a Quantisal collection device. OF to serum concentration ratios were determined, taking into account the exact volume of collected OF.Linearity was evaluated at 7 or 8 calibration levels. Accuracy criteria were fulfilled, except for pipamperone (PIP) at quality control (QC) low. The intraday precision ranged 0.88%-14.73% and interday precision ranged 1.92%-16.17%. The mean recovery from the collection pad was 37.1% at QC low and 40.3% at QC high for 1 mL of collected OF; for 0.5 mL collected OF mean recovery was 35.0% at QC low and 37.3% at QC high. When 0.1 mL OF was collected, recovery data were unreliable. Mean absolute matrix effect was 101.1% (82.0%-120.0%). OF patient samples (n = 89) containing 269 APs and metabolites were acquired and the mean volume of collected OF was 0.562 mL (0.057-1.232 mL). The OF to serum ratios were above 1 for all APs (1.54-28.50), except for aripiprazole (0.21) and zuclopenthixol (0.66). A broad range of calculated ratios for all APs was obtained.This validated ultra-high performance liquid chromatography-tandem mass spectrometric method can be used to reliably quantify APs in OF, even when recovery is low. Because the correlation between OF and serum concentrations was low and in addition results were highly variable, it can only be concluded that OF is a potentially interesting matrix, particularly for screening for noncompliance.


相关化合物

  • 还原氟哌啶醇
  • 1-[4-(4-氟苯基)-4-...

相关文献:

Antagonism by haloperidol and its metabolites of mechanical hypersensitivity induced by intraplantar capsaicin in mice: role of sigma-1 receptors.

2009-07-01

[Psychopharmacology 205 , 21-33, (2009)]

Determination of haloperidol and reduced haloperidol in human serum by liquid chromatography after fluorescence labeling based on the Suzuki coupling reaction.

2006-10-01

[Anal. Bioanal. Chem 386(3) , 719-24, (2006)]

Plasma reduced haloperidol/haloperidol ratios in schizophrenic patients treated with high dosages of haloperidol.

1994-06-01

[Eur. Neuropsychopharmacol. 4(2) , 119-26, (1994)]

Reduced haloperidol does not interfere with the antipsychotic activity of haloperidol in the treatment of acute schizophrenia.

1999-07-01

[Int. Clin. Psychopharmacol. 14(4) , 219-28, (1999)]

Correlation of clinical response (PANSS) and plasma levels of haloperidol and reduced haloperidol in schizophrenia.

1994-03-01

[Prog. Neuropsychopharmacol. Biol. Psychiatry 18(2) , 347-53, (1994)]

更多文献...