Journal of chromatography. A 2010-09-10

Use of a polar ionic liquid as second column for the comprehensive two-dimensional GC separation of PCBs.

Michal Zapadlo, Ján Krupcík, Pavel Májek, Daniel W Armstrong, Pat Sandra

文献索引:J. Chromatogr. A. 1217(37) , 5859-67, (2010)

全文:HTML全文

摘要

The orthogonality of three columns coupled in two series was studied for the congener specific comprehensive two-dimensional GC separation of polychlorinated biphenyls (PCBs). A non-polar capillary column coated with poly(5%-phenyl-95%-methyl)siloxane was used as the first ((1)D) column in both series. A polar capillary column coated with 70% cyanopropyl-polysilphenylene-siloxane or a capillary column coated with the ionic liquid 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethane-sulfonyl)imide were used as the second ((2)D) columns. Nine multi-congener standard PCB solutions containing subsets of all native 209 PCBs, a mixture of 209 PCBs as well as Aroclor 1242 and 1260 formulations were used to study the orthogonality of both column series. Retention times of the corresponding PCB congeners on (1)D and (2)D columns were used to construct retention time dependences (apex plots) for assessing orthogonality of both columns coupled in series. For a visual assessment of the peak density of PCBs congeners on a retention plane, 2D images were compared. The degree of orthogonality of both column series was, along the visual assessment of distribution of PCBs on the retention plane, evaluated also by Pearson's correlation coefficient, which was found by correlation of retention times t(R,i,2D) and t(R,i,1D) of corresponding PCB congeners on both column series. It was demonstrated that the apolar+ionic liquid column series is almost orthogonal both for the 2D separation of PCBs present in Aroclor 1242 and 1260 formulations as well as for the separation of all of 209 PCBs. All toxic, dioxin-like PCBs, with the exception of PCB 118 that overlaps with PCB 106, were resolved by the apolar/ionic liquid series while on the apolar/polar column series three toxic PCBs overlapped (105+127, 81+148 and 118+106).Copyright 2010 Elsevier B.V. All rights reserved.


相关化合物

  • 多氯联苯(Aroclor 1...
  • 多氯联苯(Aroclor 1...

相关文献:

Impacts of molt-inhibiting organochlorine compounds on epidermal ecdysteroid signaling in the fiddler crab, Uca pugilator, in vitro.

2009-11-01

[Comp. Biochem. Physiol. C. Toxicol. Pharmacol. 150(4) , 436-41, (2009)]

Extensive biodegradation of polychlorinated biphenyls in Aroclor 1242 and electrical transformer fluid (Askarel) by natural strains of microorganisms indigenous to contaminated African systems

2008-01-01

[Chemosphere 73(1) , 126-32, (2008)]

Response of bacterial isolates from Antarctic shallow sediments towards heavy metals, antibiotics and polychlorinated biphenyls.

2013-03-01

[Ecotoxicology 22(2) , 240-50, (2013)]

The inhibition of LPS-induced splenocyte proliferation by ortho-substituted and microbially dechlorinated polychlorinated biphenyls is associated with a decreased expression of cyclin D2.

2004-11-01

[Toxicology 204(1) , 61-74, (2004)]

Enhancement of aerobic microbial degradation of polychlorinated biphenyl in soil microcosms.

2003-04-01

[Environ. Toxicol. Chem. 22(4) , 699-705, (2003)]

更多文献...