Talanta 2009-01-01

Simultaneous determination of CFC-11, CFC-12 and CFC-113 in seawater samples using a purge and trap gas-chromatographic system

Serena Massolo, Paola Rivaro, Roberto Frache, Serena Massolo, Paola Rivaro, Roberto Frache, Serena Massolo, Paola Rivaro, Roberto Frache

文献索引:Talanta 80(2) , 959-66, (2009)

全文:HTML全文

摘要

We have optimized the analytical parameters of a homemade instrument for the simultaneous measurement of the chlorofluorocarbons CCl 2F 2 (CFC-12), CCl 3F (CFC-11) and C 2Cl 3F 3 (CFC-113) in seawater. Seawater samples are flame sealed into 60 ml glass ampoules avoiding any contact with the atmosphere and stored in cold, dark condition until analysis. In the laboratory, after cracking the ampoule in an enclosed chamber filled with ultra-pure nitrogen, the seawater sample is transferred to a stripping chamber, where ultra-pure nitrogen is used to purge the dissolved CFCs from the seawater. The extracted gases are then cryogenically trapped, subsequently the trap is isolated and heated and the CFCs are transferred by a carrier gas stream into a precolumn and then are separated on a gaschromatographic packed column. To separate adequately CFC-12 from N 2O, during the early part of the chromatographic run, the gas stream passes through a molecular sieve, which is then isolated and backflushed. The CFCs are detected on an electron capture detector ( 63Ni ECD). After a careful choice of the experimental conditions, the performances of the system were evaluated. The detection limits for seawater samples are: 0.0081 pmol kg −1 for CFC-12, 0.0073 pmol kg −1 for CFC-11 and 0.0043 pmol kg −1 for CFC-113. The reproducibility of replicate samples lies within 5% for the three CFCs. The system has been successfully employed for CFC measurements in seawater samples collected in the Ross Sea (Antarctica) in the framework of the Italian Antarctic research project.


相关化合物

  • 三氯氟甲烷
  • 二氯二氟甲烷
  • 1,1,2-三氟三氯乙烷

相关文献:

QSPR modeling of octanol/water partition coefficient for vitamins by optimal descriptors calculated with SMILES.

2008-04-01

[Eur. J. Med. Chem. 43 , 714-40, (2008)]

Impact of residual (18)F-fluoride in (18)F-FDOPA for the diagnosis of neuroblastoma.

2015-07-01

[Ann. Nucl. Med. 29 , 489-98, (2015)]

Multiphoton dissociation/ionization of CHCl3 and CFCl3 at 355 nm: an experimental and theoretical study.

2004-01-01

[Rapid Commun. Mass Spectrom. 18(20) , 2383-7, (2004)]

The use of vapocoolants for detumescence.

1993-10-01

[Br. J. Urol. 72(4) , 518, (1993)]

Aerosol propellant interference with clinical mass spectrometers.

1991-04-01

[J. Clin. Monit. 7(2) , 172-4, (1991)]

更多文献...