Analytica Chimica Acta 2010-07-19

Electrochemical sensor for parabens based on molecular imprinting polymers with dual-templates.

Yang Wang, Yuhua Cao, Cheng Fang, Qianqian Gong

文献索引:Anal. Chim. Acta 673(2) , 145-50, (2010)

全文:HTML全文

摘要

A selective, sensitive, rapid and reliable method based on molecularly imprinted polymers (MIPs) with dual templates to determine total content of parabens in cosmetics was developed. With methylparaben (MP) and propylparaben (PP) as dual-templates, methacrylic acid (MAA) as a functional monomer and tripropylene glycol diacrylate (TPGDA) as a cross-linker, MIPs film on a glassy carbon electrode was constructed as paraben sensor. At oxidation potential of 0.94 V (vs. SCE), the peak currents on the MIPs sensor were proportional to the concentration of parabens with square wave voltammetry. As the ratio of MP to PP in the MIPs was 1:1.25, the regression equations for four parabens were almost the same. The linear range was 20-100 microM for MP and EP, 5-100 microM for PP, and 5-80 microM for BP, with detection limit of 0.4 microM for MP and EP, 0.2 microM for the others. The total content of parabens could be calculated according to the average of these four regress equations. At least 10 times of structural analogs, such as p-hydroxybenzoic acid, p-aminobenzoic acid and phenol would not interfere with the determination of parabens. Nonanalogous coexistences such as vitamin C had no response on the sensor at all. Rapid response of the MIPs sensor was obtained within 1 min. MIPs sensor had been used to determine total content of parabens in cosmetic samples with recoveries between 98.7% and 101.8%. It reveals that the MIPs sensor with multi-templates has a potential to determine the total content of a group of homologous compounds.2010 Elsevier B.V. All rights reserved.


相关化合物

  • 对羟基苯甲酸丙酯
  • 二缩三丙二醇二丙烯...

相关文献:

Development and validation of a stability-indicating LC-UV method for the determination of pantethine and its degradation product based on a forced degradation study.

2014-08-01

[J. Pharm. Biomed. Anal. 97 , 141-50, (2014)]

Development and application of a validated stability-indicating high-performance liquid chromatographic method using photodiode array detection for simultaneous determination of granisetron, methylparaben, propylparaben, sodium benzoate, and their main degradation products in oral pharmaceutical preparations.

2011-01-01

[J. AOAC Int. 94(5) , 1447-60, (2011)]

The EpiOcular Eye Irritation Test (EIT) for hazard identification and labelling of eye irritating chemicals: protocol optimisation for solid materials and the results after extended shipment.

2015-05-01

[Altern. Lab. Anim. 43 , 101-27, (2015)]

Determination and separation of bisphenol A, phthalate metabolites and structural isomers of parabens in human urine with conventional high-pressure liquid chromatography combined with electrospray ionisation tandem mass spectrometry.

2015-03-01

[Anal. Bioanal. Chem 407(9) , 2509-18, (2015)]

Impact of induced fit on ligand binding to the androgen receptor: a multidimensional QSAR study to predict endocrine-disrupting effects of environmental chemicals.

2005-09-08

[J. Med. Chem. 48 , 5666-74, (2005)]

更多文献...