Review of Scientific Instrument 2015-10-01

Sub-50 nm metrology on extreme ultra violet chemically amplified resist--A systematic assessment.

D J Maas, T Fliervoet, R Herfst, E van Veldhoven, J Meessen, V Vaenkatesan, H Sadeghian

文献索引:Rev. Sci. Instrum. 86 , 103702, (2015)

全文:HTML全文

摘要

With lithographic patterning dimensions decreasing well below 50 nm, it is of high importance to understand metrology at such small scales. This paper presents results obtained from dense arrays of contact holes (CHs) with various Critical Dimension (CD) between 15 and 50 nm, as patterned in a chemically amplified resist using an ASML EUV scanner and measured at ASML and TNO. To determine the differences between various (local) CD metrology techniques, we conducted an experiment using optical scatterometry, CD-Scanning Electron Microscopy (CD-SEM), Helium ion Microscopy (HIM), and Atomic Force Microscopy (AFM). CD-SEM requires advanced beam scan strategies to mitigate sample charging; the other tools did not need that. We discuss the observed main similarities and differences between the various techniques. To this end, we assessed the spatial frequency content in the raw images for SEM, HIM, and AFM. HIM and AFM resolve the highest spatial frequencies, which are attributed to the more localized probe-sample interaction for these techniques. Furthermore, the SEM, HIM, and AFM waveforms are analyzed in detail. All techniques show good mutual correlation, albeit the reported CD values systematically differ significantly. HIM systematically reports a 25% higher CD uniformity number than CD-SEM for the same arrays of CHs, probably because HIM has a higher resolution than the CD-SEM used in this assessment. A significant speed boost for HIM and AFM is required before these techniques are to serve the demanding industrial metrology applications like optical critical dimension and CD-SEM do nowadays.


相关化合物

  • 3,6-二羟基邻苯二甲...

相关文献:

Fluorescence emissions of imide compounds and end-capped polyimides enhanced by intramolecular double hydrogen bonds.

2015-11-11

[Phys. Chem. Chem. Phys. 17 , 30659-69, (2015)]

Natural-cause mortality and long-term exposure to particle components: an analysis of 19 European cohorts within the multi-center ESCAPE project.

2015-06-01

[Environ. Health Perspect. 123 , 525-33, (2015)]

Flow cytometric measurement of cytoplasmic pH: a critical evaluation of available fluorochromes.

1986-07-01

[Cytometry 7(4) , 347-55, (1986)]

Ratiometric measurement of intracellular pH in cultured human keratinocytes using carboxy-SNARF-1 and flow cytometry.

1991-01-01

[Cytometry 12(2) , 127-32, (1991)]

Measurement of intracellular pH.

1990-01-01

[Methods Cell Biol. 33 , 59-69, (1990)]

更多文献...