International Archives of Occupational and Environmental Health 1991-01-01

2-Acetylfuran, a confounder in urinalysis for 2,5-hexanedione as an n-hexane exposure indicator.

T Kawai, T Yasugi, K Mizunuma, S Horiguchi, Y Uchida, O Iwami, H Iguchi, M Ikeda

文献索引:Int. Arch. Occup. Environ. Health 63(3) , 213-9, (1991)

全文:HTML全文

摘要

The apparent amount of 2,5-hexanedione, a biomarker of n-hexane expsoure in occupational health, in the urine of both exposed and non-exposed subjects varied not only as a function of the pH at which the urine sample was hydrolyzed but also depending on the capillary column used for gas chromatographic (GC) analysis of the urinary hydrolyzates after extraction with dichloromethane. The formation of a compound, identified by gas chromatography-mass spectrometry (GC-MS) as 2-acetylfuran, following acid hydrolysis was a major cause of confounding effects. This compound was hardly separated from 2.5-hexanedione on a capillary column such as DB-WAX, whereas separation could be achieved on a DB-1 capillary column. 2-Acetylfuran was formed when a urine sample was heated at a pH of less than 2 for hydrolysis, and the amount detected in urine did not differ between exposed and non-exposed subjects, indicating that the formation of 2-acetylfuran is independent of n-hexane exposure. When urinary hydrolysis is used, hydrolysis at a pH of less than 0.5, extraction with dichloromethane, and GC analysis on a non-polar capillary column are proposed to be the best analytical conditions for 2,5-hexanedione analysis in biological monitoring of exposure to n-hexane.


相关化合物

  • 2-乙酰基呋喃

相关文献:

Quantification of furanic derivatives in fortified wines by a highly sensitive and ultrafast analytical strategy based on digitally controlled microextraction by packed sorbent combined with ultrahigh pressure liquid chromatography.

2015-02-13

[J. Chromatogr. A. 1381 , 54-63, (2015)]

Dose-dependent increase in 2,5-hexanedione in the urine of workers exposed to n-hexane.

1991-01-01

[Int. Arch. Occup. Environ. Health 63(4) , 285-91, (1991)]

[Acute hepatitis in subjects exposed to 2-acetylfuran and hydrazine].

1983-01-01

[Med. Lav. 74(4) , 284-90, (1983)]

Spectral studies on Co(II), Ni(II) and Cu(II) complexes with thiosemicarbazone (L1) and semicarbazone (L2) derived from 2-acetyl furan.

2007-04-01

[Spectrochim. Acta. A. Mol. Biomol. Spectrosc. 66(4-5) , 1347-51, (2007)]

Comparison of 2-acetylfuran formation between ribose and glucose in the Maillard reaction.

2008-12-24

[J. Agric. Food Chem. 56(24) , 11997-2001, (2008)]

更多文献...