Determination of piroxicam and its major metabolites in the plasma, urine and bile of humans by high-performance liquid chromatography.
P A Milligan
文献索引:J. Chromatogr. A. 576(1) , 121-8, (1992)
全文:HTML全文
摘要
A simple and sensitive liquid chromatographic method with ultraviolet detection is described for the determination of the nonsteroidal anti-inflammatory drug piroxicam and its major metabolites in human plasma, urine and bile. Separation of these components occurs on a reversed phase C10CN column with a mobile phase consisting of acetonitrile-water-sodium dihydrogenphosphate solution. The detection limit of the assay was 50 ng/ml with intra- and inter-assay coefficients of variation for piroxicam of the order of 2 and 5%, respectively. The assay linearity was good (typically r = 0.9999). This method can be readily utilised for clinical pharmacokinetic and mass-balance studies.
相关化合物
相关文献:
1988-08-01
[Arzneimittelforschung 38(8) , 1089-92, (1988)]
[J. Chromatogr. A. 382 , 382-8, (1986)]
1995-11-03
[J. Chromatogr. B, Biomed. Appl. 673(1) , 142-6, (1995)]
1998-08-01
[Analyst 123(8) , 1749-52, (1998)]
1998-07-01
[J. Pharm. Biomed. Anal. 17(3) , 515-24, (1998)]