CardioVascular and Interventional Radiology 2007-01-01

Value of single-dose contrast-enhanced magnetic resonance angiography versus intraarterial digital subtraction angiography in therapy indications in abdominal and iliac arteries.

Philipp J Schaefer, Fritz K W Schaefer, Stefan Mueller-Huelsbeck, Markus Both, Martin Heller, Thomas Jahnke

文献索引:Cardiovasc. Intervent. Radiol. 30(3) , 376-82, (2007)

全文:HTML全文

摘要

The objective of the study was to prove the value of single-dose contrast-enhanced magnetic resonance angiography [three-dimensional (3D) ceMRA] in abdominal and iliac arteries versus the reference standard intra-arterial digital subtraction angiography (i.a.DSA) when indicating a therapy. Patients suspected of having abdominal or iliac artery stenosis were included in this study. A positive vote of the local Ethics Committe was given. After written informed consent was obtained, 37 patients were enrolled, of which 34 were available for image evaluation. Both 3D ceMRA and i.a. DSA were performed for each patient. The dosage for 3D ceMRA was 0.1 mmol/kg body weight in a 1.5-T scanner with a phased-array coil. The parameters of the 3D-FLASH sequence were as follows: TR/TE 4.6/1.8 ms, effective thickness 3.5 mm, matrix 512 x 200, flip angle 30 degrees , field of view 420 mm, TA 23 s, coronal scan orientation. Totally, 476 vessel segments were evaluated for stenosis degree by two radiologists in a consensus fashion in a blinded read. For each patient, a therapy was proposed, if clinically indicated. Sensitivity, specificity, positive and negative predictive values, and accuracy for stenoses > or = 50% were 68%, 92%, 44%, 97%, and 90%, respectively. In 13/34 patients, a discrepancy was found concerning therapy decisions based on MRA findings versus therapy decisions based on the reference standard DSA. The results showed that the used MRA imaging technique of abdominal and iliac arteries is not competitive to i.a. DSA, with a high rate of misinterpretation of the MRAs resulting in incorrect therapies.


相关化合物

  • 碘喷托

相关文献:

[Determination of the distribution volume of contrast media solutions injected intrahepatically: pre-pilot studies for intratumoral gene therapy].

2002-03-01

[Rofo. 174(3) , 357-62, (2002)]

Influence of two non-ionic radiographic contrast media with different osmolalities on coagulation in invasive cardiology. A prospective, randomised comparative study.

2002-11-01

[Acta radiol. 43(6) , 617-22, (2002)]

Low-high and high-low biphasic injection forms in computed tomography examinations of the upper abdomen.

2006-02-01

[Acta radiol. 47(1) , 10-4, (2006)]

Cerebral CT angiography using a small volume of concentrated contrast material with a test injection method: optimal scan delay for quantitative and qualitative performance.

2012-09-01

[Br. J. Radiol. 85(1017) , e748-55, (2012)]

[Severe reactions to iodinated contrast agents: is anaphylaxis responsible?].

2001-09-01

[J. Radiol. 82(9 Pt 1) , 973-7, (2001)]