Analytical chemistry 1999-12-01

Radionuclide sensors based on chemically selective scintillating microspheres:  renewable column sensor for analysis of (99)tc in water.

O B Egorov, S K Fiskum, M J O'Hara, J W Grate

文献索引:Anal. Chem. 71 , 5420, (1999)

全文:HTML全文

摘要

A method for chemically selective radiometric sensing of non-γ-emitting radionuclides in solution is described. Using scintillating microspheres with selective radionuclide uptake properties, radiochemical separation and radiometric detection steps are integrated within a sensor device. These microspheres are loaded into a renewable minicolumn that serves to capture, preconcentrate, and separate radionuclides. The preconcentrating minicolumn also localizes and retains radionuclides within a detector of well-defined geometry and emits a photometric signal. The sensor material in the column can either be regenerated with eluent chemistries or be renewed by fluidic replacement of the beads. The latter method allows the use of materials that bind analytes irreversibly or are unstable under regeneration conditions. Radionuclide-selective scintillating microspheres were prepared by coimmobilization of scintillating fluors and selective organic extractants within the pores of an inert polymeric support. Preparation and characterization of microspheres, and their use for selective quantitative sensing of (99)Tc(VII), is described in detail. A sensor-based procedure for (99)Tc(VII) analysis was developed and successfully applied toward the determination of (99)Tc(VII) in groundwater samples from the Hanford site, using standard addition techniques for quantification. Using a 50-mL sample volume and signal accumulation time of 30 min, the detection limit for (99)Tc(VII) was 0.37 dpm/mL (9.8 pg/mL).


相关化合物

  • 1,4-双(2-甲基苯乙...

相关文献:

Ultrasonic degradation of schizophyllan, an antitumor polysaccharide produced by Schizophyllum commune Fries.

1981-02-16

[Carbohydr. Res. 89 , 121, (1981)]

Evaluation of flow cell detector configurations combining simultaneous preconcentration and scintillation detection for monitoring of pertechnetate in aqueous media.

2006-04-01

[Anal. Chem. 78 , 2254, (2006)]

Determination of 235U/238U atom ratio in uranium samples using liquid scintillation counting (LSC).

2009-01-15

[Analyst 119 , 465, (1994)]

Fluorescence anisotropy of tyrosinate anion using one-, two- and three-photon excitation: tyrosinate anion fluorescence.

2013-03-01

[J. Fluoresc. 23 , 339-47, (2013)]

Two-photon absorption cross-sections of reference dyes: a critical examination.

2008-01-11

[ChemPhysChem 9(1) , 111-6, (2008)]

更多文献...