Stereospecific high-performance liquid chromatographic determination of tocainide.
R A Carr, R T Foster, D Freitag, F M Pasutto
文献索引:J. Chromatogr. A. 566(1) , 155-62, (1991)
全文:HTML全文
摘要
A sensitive high-performance liquid chromatographic assay was developed for the determination of tocainide enantiomers in plasma. Following extraction of tocainide from plasma, the enantiomers were derivatized with S-(+)-1-(1-naphthyl)ethylisocyanate. The resulting diastereomers were separated and quantified using normal-phase chromatography with fluorescence detection set at 220/345 nm (excitation/emission). The peaks, resolved with a resolution factor greater than 1.5, were free from interference. Linearity was established over the concentration range 0.25-10.0 mg/l for each enantiomer in plasma (r2 greater than 0.998). The inter-assay variability was less than 10% at all concentrations examined. The method can be used to determine the pharmacokinetics of tocainide enantiomers in man.
相关化合物
相关文献:
1991-01-01
[Biomed. Chromatogr. 5(1) , 43-6, (1991)]
1991-09-01
[Pharm. Res. 8(9) , 1195-8, (1991)]
1995-10-06
[J. Chromatogr. B, Biomed. Appl. 672(1) , 89-96, (1995)]
[J. Chromatogr. A. 621(2) , 225-9, (1993)]
1991-12-01
[Pharm. Res. 8(12) , 1528-32, (1991)]