Talanta 1998-08-01

On-line preconcentration of mercury by sorption on an anion-exchange resin loaded with 1,5-bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide and determination by cold-vapour inductively coupled plasma atomic emission.

P Cañada Rudner, A Garcia de Torres, J M Cano Pavón, F Sanchez Rojas

文献索引:Talanta 46 , 1095-1105, (1998)

全文:HTML全文

摘要

1,5-Bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex) has been used for the on-line preconcentration of mercury from biological samples and waters prior to its determination by inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 2 M HNO(3) and mixed on-line with SnCl(2). The optimum experimental conditions were evaluated for the continuous preconcentration of Hg, the direct generation of mercury vapour and the final determination of this element by ICP-AES. The enrichment, together with low blank levels of the optimized procedure, allow the simple determination of this toxic element at concentrations down to a few nanograms per milliliter. The proposed method has a linear calibration range 5-1000 ng ml(-1) of mercury, with a detection limit of 4 ng ml(-1) (S/N=3) and a sampling rate of 40 h(-1), investigated with a 9 ml sample volume. The precision of the method (evaluated as the relative standard deviation obtained after analyzing ten series of ten replicates) was +/-3.6% at the 10 ng ml(-1) level of Hg(II) and +/-1.3% at the 100 ng ml(-1) level. The accuracy of the method was examined by the analysis of certified reference materials.


相关化合物

  • 离子交换树酯,1×4

相关文献:

On-line ion-exchange preconcentration and determination of traces of platinum by electrothermal atomic absorption spectrometry.

2003-04-01

[Anal. Bioanal. Chem 375 , 1229-1233, (2003)]

On-line preconcentration of rhodium on an anion-exchange resin loaded with 1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydrazide and its determination in environmental samples.

2004-09-08

[Talanta 64 , 230-236, (2004)]

Synthesis of new hypoxia markers EF1 and [18F]-EF1.

1999-12-01

[Appl. Radiat. Isot. 51(6) , 643-50, (1999)]

Borate complexes of x-ray iodinated contrast agents: characterization and sorption studies for their removal from aqueous media.

2012-02-29

[J. Hazard. Mater. 205-206 , 10-16, (2012)]

Apolipoprotein E isoform-specific disruption of phosphoinositide hydrolysis: protection by estrogen and glutathione.

2001-08-24

[FEBS Lett. 504(1-2) , 45-9, (2001)]

更多文献...