Australasian Journal of Dermatology 2006-05-01

Occupational allergic contact dermatitis to cobalt octoate included as an accelerator in a polyester resin.

Namrata S Anavekar, Rosemary Nixon

文献索引:Australas. J. Dermatol. 47(2) , 143-4, (2006)

全文:HTML全文

摘要

A 46-year-old woman, who worked as a laminator of spa baths, presented with hand dermatitis, which was suspected to be related to her occupation. Patch testing revealed strong reactions to both cobalt chloride and a polyester resin that the patient had been using at her workplace. She also reacted to latex and had been wearing cotton gloves underneath rubber gloves at work. It was later discovered that cobalt octoate (synonym: cobalt-2-ethylhexanoate), a compound not listed on the manufacturer's material safety data sheet, was included as an accelerator in the polyester resin. She was then tested to cobalt octoate, which was also strongly positive. Her successful treatment included protection of her hands at work with cotton lined PVC gloves. This case highlights the role of cobalt salts as sensitizers and their presence as accelerators used in polyester resins, and the importance of recognizing concomitant latex allergy that may complicate occupational dermatitis. It also illustrates the difficulties in relying on material safety data sheets to identify all possible allergens.


相关化合物

  • 2-乙基己酸钴

相关文献:

Offset printer's occupational allergic contact dermatitis caused by cobalt-2-ethylhexoate.

1996-01-01

[Contact Dermatitis 34(1) , 67-8, (1996)]

Occupational cobalt-allergic contact dermatitis resulting from polyester resin.

2010-11-01

[Contact Dermatitis 63(5) , 292-4, (2010)]

更多文献...