前往化源商城

European Journal of Mass Spectrometry 2014-01-01

Rapid and sensitive determination of diacetylpolyamines in human fingernail by ultraperformance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

Jun Zhe Min, Yuka Morota, Ying-Zi Jiang, Gao Li, Dongzhou Kang, Hai-fu Yu, Koichi Inoue, Kenichiro Todoroki, Toshimasa Toyo'oka

文献索引:Eur. J. Mass Spectrom. (Chichester, Eng.) 20(6) , 477-86, (2015)

全文:HTML全文

摘要

A rapid and sensitive ultraperformance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed and validated for quantitatively determining diacetylpolyamines in the human fingernail. N(1),N(8)-diacetylspermidine (DiAct-Spd), N(1),N(12)- diacetylspermine (DiAct-Spm) and 1,6-diaminohexane (DAH) the [internal standard (IS)] were extracted from human fingernail samples by MeOH: 5 M HCl solution, followed by 4-(N,N-dimethylaminosulfonyl)-7-fluoro- 2,1,3-benzoxadiazole (DBD-F) derivatization, and then separated on an ACQUITY BEH C18 column with a gradient elution of acetonitrile and water containing 0.1% formic acid. The derivatives of the diacetylpolyamines were fully separated within a short run time (3.0 min). The triple quadrupole mass spectrometric detection was performed in the multiple reactions monitoring (MRM) mode by the UPLC-ESI- MS/MS system in the positive ionization mode. MRM using the fragmentation transitions of m/z 455.20→ 100.07, 737.25 → 100.07 and 567.10 → 479.07 in the positive ESI mode was performed to quantify DiAct-Spd, DiAct-Spm and IS, respectively. The calibration curve is between 0.04 ng mL(-1) for DiAct-Spd and DiAct-Spm. The detection limits (signal to noise ratio of five) were 5-10 pg mL(-1). A good linearity was achieved from the calibration curves (r(2) >0.9999), and the intra-day and inter-day assay precisions were less than 7.06%. Furthermore, the recoveries (%) of the diacetylpolyamines spiked in the human fingernails were 79.18-97.11. The present method proved that the high sensitivity is characterized by the specificity and feasibility of the sample analysis. Consequently, the proposed method was used to analyze human fingernail samples from 15 lung- cancer patients and 22 healthy volunteers. Diacetylpolyamines were detected from the fingernails of the lung- cancer patients for the first time. The concentration of DiAct-Spd in the lung-cancer patient group tended to be higher than those in the healthy volunteers.

相关化合物

结构式 名称/CAS号 全部文献
甲酸 结构式 甲酸
CAS:64-18-6
盐酸 结构式 盐酸
CAS:7647-01-0
乙腈 结构式 乙腈
CAS:75-05-8
甲醇 结构式 甲醇
CAS:67-56-1
十二烷基硫酸钠 结构式 十二烷基硫酸钠
CAS:151-21-3
三氟乙酸(TFA) 结构式 三氟乙酸(TFA)
CAS:76-05-1
无水硼砂 结构式 无水硼砂
CAS:1330-43-4
1,6-己二胺 结构式 1,6-己二胺
CAS:124-09-4
氯化氢甲醇溶液 结构式 氯化氢甲醇溶液
CAS:132228-87-6