前往化源商城

Analytical and Bioanalytical Chemistry 2015-07-01

"Dilute-and-inject" multi-target screening assay for highly polar doping agents using hydrophilic interaction liquid chromatography high resolution/high accuracy mass spectrometry for sports drug testing.

Christian Görgens, Sven Guddat, Anne-Katrin Orlovius, Gerd Sigmund, Andreas Thomas, Mario Thevis, Wilhelm Schänzer

文献索引:Anal. Bioanal. Chem 407 , 5365-79, (2015)

全文:HTML全文

摘要

In the field of LC-MS, reversed phase liquid chromatography is the predominant method of choice for the separation of prohibited substances from various classes in sports drug testing. However, highly polar and charged compounds still represent a challenging task in liquid chromatography due to their difficult chromatographic behavior using reversed phase materials. A very promising approach for the separation of hydrophilic compounds is hydrophilic interaction liquid chromatography (HILIC). Despite its great potential and versatile advantages for the separation of highly polar compounds, HILIC is up to now not very common in doping analysis, although most manufacturers offer a variety of HILIC columns in their portfolio. In this study, a novel multi-target approach based on HILIC high resolution/high accuracy mass spectrometry is presented to screen for various polar stimulants, stimulant sulfo-conjugates, glycerol, AICAR, ethyl glucuronide, morphine-3-glucuronide, and myo-inositol trispyrophosphate after direct injection of diluted urine specimens. The usage of an effective online sample cleanup and a zwitterionic HILIC analytical column in combination with a new generation Hybrid Quadrupol-Orbitrap® mass spectrometer enabled the detection of highly polar analytes without any time-consuming hydrolysis or further purification steps, far below the required detection limits. The methodology was fully validated for qualitative and quantitative (AICAR, glycerol) purposes considering the parameters specificity; robustness (rRT < 2.0%); linearity (R > 0.99); intra- and inter-day precision at low, medium, and high concentration levels (CV < 20%); limit of detection (stimulants and stimulant sulfo-conjugates < 10 ng/mL; norfenefrine; octopamine < 30 ng/mL; AICAR < 10 ng/mL; glycerol 100 μg/mL; ETG < 100 ng/mL); accuracy (AICAR 103.8-105.5%, glycerol 85.1-98.3% at three concentration levels) and ion suppression/enhancement effects.

相关化合物

结构式 名称/CAS号 全部文献
乙酸铵 结构式 乙酸铵
CAS:631-61-8
乙腈 结构式 乙腈
CAS:75-05-8
甲醇 结构式 甲醇
CAS:67-56-1
尿素 结构式 尿素
CAS:57-13-6
甘油 结构式 甘油
CAS:56-81-5
乙酸-12C2 结构式 乙酸-12C2
CAS:1173022-32-6
冰醋酸 结构式 冰醋酸
CAS:64-19-7
5-氨基-4-甲酰胺咪唑 结构式 5-氨基-4-甲酰胺咪唑
CAS:360-97-4
雄诺龙 结构式 雄诺龙
CAS:521-18-6
阿卡地辛 结构式 阿卡地辛
CAS:2627-69-2